2.2.4 Phase Locking the Time-Base Clocks of Multiple ePWM Modules
2.2.5 Time-base Counter Modes and Timing Waveforms
0000
EPWMxSYNCI
TBCTR[15:0]
CTR_dir
CTR = zero
CNT_max
CTR = PRD
0xFFFF
TBPHS
(value)
TBPRD
(value)
Time-Base (TB) Submodule
The TBCLKSYNC bit can be used to globally synchronize the time-base clocks of all enabled ePWM
modules on a device. This bit is part of the DSPs clock enable registers and is described in the specific
device version of the System Control and Interrupts Reference Guide listed in
Section 1
. When
TBCLKSYNC = 0, the time-base clock of all ePWM modules is stopped (default). When TBCLKSYNC = 1,
all ePWM time-base clocks are started with the rising edge of TBCLK aligned. For perfectly synchronized
TBCLKs, the prescaler bits in the TBCTL register of each ePWM module must be set identically. The
proper procedure for enabling the ePWM clocks is as follows:
1. Enable the individual ePWM module clocks. This is described in the specific device version of the
System Control and Interrupts Reference Guide listed in
Section 1
.
2. Set TBCLKSYNC = 0. This will stop the time-base clock within any enabled ePWM module.
3. Configure the prescaler values and desired ePWM modes.
4. Set TBCLKSYNC = 1.
The time-base counter operates in one of four modes:
Up-count mode which is asymmetrical.
Down-count mode which is asymmetrical.
Up-down-count which is symmetrical
Frozen where the time-base counter is held constant at the current value
To illustrate the operation of the first three modes, the following timing diagrams show when events are
generated and how the time-base responds to an EPWMxSYNCI signal.
Figure 2-7. Time-Base Up-Count Mode Waveforms
30
ePWM Submodules
SPRU791D – November 2004 – Revised October 2007