页码 156
 
HUAWEI MC509 CDMA LGA Module 
AT Command Interface Specification 
Basic Configuration Commands 
 
Issue 01 (2011-08-26) 
Huawei Proprietary and Confidential 
Copyright © Huawei Technologies Co., Ltd. 
26 
 
2.2 S3Command Line Termination Character 
2.2.1 Syntax 
Command 
Possible Response(s) 
S3=<value> 
<CR><LF>OK<CR><LF> 
S3? 
<CR><LF><value><CR><LF> 
<CR><LF>OK<CR><LF> 
 
2.2.2 Interface Description 
This command sets the command line termination character S3. S3 saves the 
command line termination character in the ASCII code format. The character is sent 
by the TE to indicate the termination of a command line, which is identified and 
confirmed by the MT. The character is also sent by the MT to compose the headers, 
tails, and end flags of the result code and response information. 
When running S3=<value> to set S3, use the current S3 as the termination character. 
The new S3 will be immediately returned with the result code. 
2.2.3 Parameter Description 
<value>: A decimal number ranges from 000 to 127, indicating the ASCII code of the 
character. The default value is 013
 
 
ATS3=1 is equivalent to ATS3=001
 
2.3 S4Response Format Character 
2.3.1 Syntax 
Command 
Possible Response(s) 
S4=<value> 
<CR><LF>OK<CR><LF> 
S4? 
<CR><LF><value><CR><LF> 
<CR><LF>OK<CR><LF>