7 Windows/Dialogs 
 
 
 
7.11.3 Configuration of Data Access Mode 
When data access mode is selected while bus mode and disassemble mode are unselected, trace 
information is displayed in data access mode. Data access mode is configured as shown below. 
 
 
 
1.  Data access display area: Shows data access information. If the information displayed here is 
"000400 1234 W," for example, it means that data "1234H" was written to the address 000400H 
in 2-byte width. 
 
Other display areas are the same as in bus mode. 
 
In addition to data access information, the window can display source line information in combination. 
In this case, the display will be similar to the one shown below. 
 
 
 