12.3.5 Hardware Event 
• 
If you specify word-length (2-byte length) data from an odd address as an event in the following 
data accesses, the event is not detected. Also, even when any other bit of the address that 
contains a specified bit is accessed during bit access, the event may become effective.   
Hardware Break Event   
Real-time Trace Event   
Time Measurement Event   
• 
To detect a byte access to an odd address in 8 bit bus width, specify the compare data to 
HI-BYTE.  
• 
You cannot specify a PID data in word-length, when the specified PID address is an odd address.   
 
• 
Examples to specify the event for data access with its value comparison. 
Address 
Access size 
16bit data bus 
8bit data bus 
Even Address 
WORD 
ex.: mov.w #1234h, 8000h 
Address: 8000h 
Data: 1234h 
Data Mask: Don't care 
<- 
Even Address 
BYTE 
ex.: mov.b #34h, 8000h 
Address: 8000h 
Data: 34h 
Data Mask: 00FFh 
<- 
Odd Address 
WORD 
ex.: mov.w #1234h, 8001h 
Not supported 
<- 
Odd Address 
BYTE 
ex.: mov.b #34h, 8001h 
Address: 8001h 
Data: 34h 
Data Mask: 00FFh 
Address: 8001h 
Data: 3400h 
Data Mask: FF00h 
 
12.3.6 Operating frequency of MCU 
You need to specify the operating frequency of mcu for debugger to calculate the time for Trace 
window, Time measurement window, or other functions. 
You can set it in MCU tab of INIT dialog box. If you use the mcu at 10MHz div 8, please enter 10 and 
8 to edit boxes. 
 
12.3.7 The correspondence OS version of task pause function 
The task pause function is available when downloading a target program in which the system for the 
task pause function, supported by MR30 V.3.00 or later version, is installed. 
If the MR30 version is V.3.00 Release 1, the following phenomenon may occur.   
• 
If a program issues a system call such as rel_wai or irel_wai to a task which is changed to 
"Pause" using the task pause function, the "Pause" state of the task is reset. 
In this case, the MR Task Pause window shows the task information different from the real task 
state.  
 
This phenomenon will not occur on a target program in which MR30 V3.10 Release 1 or later is 
installed.