Renesas M16C PC4701 用户手册

下载
页码 294
 
5 Setup the Debugger 
 
5.2.3 Setting of the LAN Interface 
LAN communication uses a LAN interface of the personal computer. 
Before using LAN, you must register the emulator IP address, port number and subnet mask to the 
emulator itself (Otherwise, LAN is not available). 
Then, set LAN communication. 
LAN communication can only be used on the PC4701U/HS emulator. 
 
It is necessary for LAN communication with emulators to set the registry. For details, see "3.3 Setting 
before emulator starts
 ".   
 
5.2.3.1 Setting the IP Address and Subnet Mask 
Start the debugger using other communication method. After it gets started, select Menu - 
[Setup]->[Emulator]->[ System...] to open the Init dialog. Then, click the Target button of MCU tab. 
The Target dialog will be opened. 
 
 
 
Specify the emulator IP address in the IP Address field, port number in the Port field, and subnet 
mask in the SubNetMask field. (The emulator IP address must be registered in the network 
environment in advance.) 
When the PC7501 or PC4701U is used, the Default Gateway area becomes effective. Please specify 
the IP address of the default gateway. When the PC7501 or PC4701U is used on the identical sub net 
mask of identical network, it is possible to omit the IP address of the default gateway.   
• 
Specify the IP address, subnet mask and Default Gateway in decimal byte by byte, by separating 
every 4 bytes with a period. For details on the IP address and subnet mask, consult with your 
network manager.   
• 
A port number set in the Port field is used to identify the communication process of the server 
(emulator) in LAN (TCP/IP) communications. Specify the port number which has been set in the 
emulator in hexadecimal. (Do not add a prefix which shows a base.) 
 
Click the "OK" button in the Target dialog. The Target dialog is then closed and the Init dialog 
appears again. Click the "OK" button. 
Then, exit from the debugger. 
 
 
47