Operational Specifications 
3.2.1  SH7086 Power Supply Select Jumpers (JP1) 
Rev.1.0 Feb 6, 2007 
3-18
REJ10J0916-0100  
 
 
 
3.2.1  SH7086 Power Supply Select Jumpers (JP1) 
 
The JP1 allow the sources for the SH7086 power supply voltages to be selected. 
Figure3.2.2 shows the SH7086 power supply voltage select jumper assignment (JP1). Table3.2.1 lists the jumper 
setting for selecting SH7086 Power Supply Voltage (JP1). 
 
Top View of the
Component Side
Board
Edge
Board
Edge
JP
1
1
2
3
PWR
S
EL
 
 
Figure3.2.2    SH7086 Power Supply Voltage Select Jumpers Assignment (JP1) 
 
Table3.2.1    Jumper Setting for Selecting SH7086 Power Supply Voltage (JP1) 
Jumper Setting 
Function 
1 - 2 
5V fixed power supply voltage (supplied from J5) 
JP1 
 PWRSEL 
2 - 3 
External power supply voltage (supplied from J4) 
    : Initial Setting 
Note: Do not change jumper settings during the operation of M3A-HS86. Ensure to turn off the power for the 