3.  Insert the board’s edge connector into the bus slot. 
Use the slot’s board guides as you insert the board 
edge connector into the slot. Apply pressure only to 
the top edge of the board, and press firmly until the 
edge connector is securely seated in the slot. 
 
4.  Replace and tighten the retaining screw to secure the 
board. If the screw is not installed and you attach a 
CT Bus cable to the board, the board may be 
accidentally unseated from the slot. 
5.  To install an additional board, select an empty PCI 
slot adjacent to the location of the previous board, 
and repeat (the second part of) step 2 through step 4. 
 
 
5. Attach CT Bus Cable to Board (optional) 
Colored Stripe (Pin 1)
 
If you use the board in stand-alone mode, skip the 
instructions in this section. 
Use a CT Bus cable to connect your board to other 
CT Bus form-factor boards in the system.  
  Caution! To preserve the electrical integrity of the 
CT Bus, use a CT Bus cable with the appropriate 
number of connectors (“drops”). We recommend that no 
more than two connectors at either end of the cable be 
left unused. In addition, it is preferable to distribute the 
installed boards in slots along the length of the CT Bus 
cable rather than clustered in one area. 
Attach the CT Bus cable to the Dialogic board as 
follows: 
1.  Attach the end connector on the CT Bus cable to the 
CT Bus edge connector on the top edge of the first 
board in the sequence. The connectors are designed 
to fit together one way only. If the connector does 
not seat fully on the board, turn the cable around and 
try again. Make sure that the colored stripe on the 
cable faces the rear bracket. 
2.  Attach the cable to the next board until all boards are 
connected by the cable. 
Your CT Bus cable may 
have a different number 
of connectors (drops).
Colored Stripe
(Pin 1)
 
3.  If the cable has extra connectors or is loose, tuck the 
cable down so that it does not snag when you replace 
the computer cover. See the Caution given earlier in 
this section. 
 
 
6. Connect CT Bus/SCbus Adapter (optional) 
If you use the board in stand-alone mode, skip the 
instructions in this section.  
To connect your board to SCbus form-factor boards, use 
the CT Bus/SCbus adapter (part number  
882-757-xx). You may use only one CT Bus/SCbus 
adapter per system
1.  Before installing the adapter, the Dialogic
®
 boards in 
your chassis must be positioned in the correct order. 
The board on which the adapter is installed must be 
inserted in the first PCI slot adjacent to an ISA slot. 
Locate this board. 
2.  Align pin 1 of the adapter with pin 1 of the edge 
connector on the board. Press the adapter onto the 
board with the SCbus cable connector facing the rear 
edge of the board. 
PCI Slots
ISA Slots
D/xxx JCT
Board
Colored Stripe
(Pin 1 Indicator)
D/xxx
Board
SCbus
Cable
CT Bus
Cable
CT Bus / SCbus
Adapter
 
For more information, see the hardware installation 
instructions for the CT Bus/SCbus Adapter. 
7. Complete Board Installation 
After you have installed the board(s) and if applicable 
attached cables and adapter, replace the computer cover 
and re-attach power cords. 
 
 
8.  Connect External Cables 
   
Each RJ-11 jack on the rear bracket of the voice 
board supports a single voice channel. Use each RJ-
11 jack and phone cable to connect each channel to 
an analog PBX or standard telephone outlet. 
   
Since this board emulates a standard telephone, a 
standard telephone will not function when directly 
attached to the board. 
Channel 1
Channel 2
Channel 3
Channel 4
To analog 
PBX 
or 
standard 
telephone 
outlet
Rear 
bracket 
on board
1
2
3
4
Pin
5
6
2
5
4
3
6
1
J1-J4 on the 
VFX/41JCT-LS Board
RJ-11 Connector
Signal
Unused
Station - Earth Recall
Unused
Station - Ring
Station - Tip
Unused
 
 
Note: 
Connect the Earth Recall signal to pin 2. DO 
NOT connect Tip or Ring lines to pin 2 or improper 
operation of the VFX/41JCT-LS will result. 
 
 
9.  Install Software, Configure and Test 
Install the Dialogic
®
 software release and configure the 
Dialogic
®
 boards as described in the 
Dialogic
®
Installation and Configuration Guide for your 
operating system.  
Your application software or Dialogic software release 
may have special installation or configuration 
requirements. Be sure to read your software 
documentation including release note information 
before you install the software. 
Note: 
If you are adding hardware to an existing system, 
you do not need to uninstall existing Dialogic
®
 
software. 
 
 
10. Warranty and Return Information 
 
Warranty Period 
For specific warranty information for this board, refer to 
the Warranty section of the Products page, located at this 
URL: http://www.dialogic.com/warranties/.  
 
Contacting Technical Support 
Dialogic provides technical support for its products 
through a network of value added distributors who are 
trained to answer technical questions on installing and 
configuring Dialogic
®
 products.  If you are unsure how 
to contact your support channel, please call Dialogic 
in the United States at 973-967-6600 (9am-5pm EST) 
and we will assist in obtaining the appropriate support 
channel.  Outside the United States please refer to 
 to obtain 
local contact information. 
 
Dialogic also provides direct support via Dialogic
®
 Pro™ 
Services agreements.  For more details of direct support 
from Dialogic please refer to: 
 
Returning a Product 
To return a board for warranty repair or any other returns, 
please refer to the following: 
.  To return a 
board for warranty repair, please refer to the following: 
http://www.dialogic.com/support/hwfaults.  For all other 
returns, contact your vendor or Dialogic Customer Support 
(for more information, see 
  ). 
 
11. Sales Assistance 
 
If you have a sales question, please contact your 
local Sales Representative or the Regional Sales Office 
for your area. Address, telephone and fax numbers, are 
available at the Dialogic website located at: 
To purchase Dialogic
®
 products, please refer to the 
following website to locate the appropriate supplier.  
All contents of this document are furnished for informational use only and 
are subject to change without notice and do not represent a commitment on 
the part of Dialogic Corporation or its subsidiaries (“Dialogic”). 
Reasonable effort is made to ensure the accuracy of the information 
contained in the document. However, Dialogic does not warrant the 
accuracy of this information and cannot accept responsibility for errors, 
inaccuracies or omissions that may be contained in this document.  
INFORMATION IN THIS DOCUMENT IS PROVIDED IN 
CONNECTION WITH DIALOGIC
®
 PRODUCTS. NO LICENSE, 
EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY 
INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS 
DOCUMENT. EXCEPT AS PROVIDED IN A SIGNED AGREEMENT 
BETWEEN YOU AND DIALOGIC, DIALOGIC ASSUMES NO 
LIABILITY WHATSOEVER, AND DIALOGIC DISCLAIMS ANY 
EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR 
USE OF DIALOGIC PRODUCTS INCLUDING LIABILITY OR 
WARRANTIES RELATING TO FITNESS FOR A PARTICULAR 
PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY 
INTELLECTUAL PROPERTY RIGHT OF A THIRD PARTY. 
Dialogic products are not intended for use in medical, life saving, life 
sustaining, critical control or safety systems, or in nuclear facility 
applications. 
It is possible that the use or implementation of any one of the concepts, 
applications, or ideas described in this document, in marketing collateral 
produced by or on web pages maintained by Dialogic may infringe one or 
more patents or other intellectual property rights owned by third parties. 
Dialogic does not provide any intellectual property licenses with the sale of 
Dialogic products other than a license to use such product in accordance 
with intellectual property owned or validly licensed by Dialogic and no 
such licenses are provided except pursuant to a signed agreement with 
Dialogic. More detailed information about such intellectual property is 
available from Dialogic’s legal department at 9800 Cavendish Blvd., 5
th
 
Floor, Montreal, Quebec, Canada H4M 2V9. Dialogic encourages all 
users of its products to procure all necessary intellectual property 
licenses required to implement any concepts or applications and does 
not condone or encourage any intellectual property infringement and 
disclaims any responsibility related thereto. These intellectual property 
licenses may differ from country to country and it is the responsibility 
of those who develop the concepts or applications to be aware of and 
comply with different national license requirements.
  
Dialogic, Diva, Eicon, Eicon Networks, Eiconcard and SIPcontrol, among 
others, are either registered trademarks or trademarks of Dialogic. 
Dialogic's trademarks may be used publicly only with permission from 
Dialogic. Such permission may only be granted by Dialogic’s legal 
department at 9800 Cavendish Blvd., 5th Floor, Montreal, Quebec, Canada 
H4M 2V9. Any authorized use of Dialogic's trademarks will be subject to 
full respect of the trademark guidelines published by Dialogic from time to 
time and any use of Dialogic’s trademarks requires proper 
acknowledgement.  The names of actual companies and products mentioned 
herein are the trademarks of their respective owners.