TANDBERG D1320203 用户手册

下载
页码 39
TANDBERG 3G Gateway 
                                                  Data port Command Interface User Guide
 
2. 
Connecting to the Data port Command Interface through the RS-232 port. 
The RS-232 port is a 9-pin, female, sub-D connector located on the front of the 3G Gateway. The port is 
configured as a DCE (Data Communications Equipment). The RS-232 port is default set to 115200 baud, 8 
data bits, none parity and 1 stop bit from factory. The RS-232 port is also referred to as the Data port. 
2.1. 
Hardware and Cabling 
The pin outs for the RS-232 are defined in the following table (the DTE, Data Terminal Equipment, could be 
a PC or other device capable of serial communication). 
 
Pin no 
Signal 
Description 
Direction 
CD 
Carrier detect 
To DTE 
2 RD 
Receive 
data 
To 
DTE 
TD 
Transmit data 
From DTE 
DTR 
Data terminal ready 
From DTE 
5  
Ground 
 
DSR 
Data set ready 
To DTE 
RTS 
Ready to send 
From DTE 
CTS 
Clear to send 
To DTE 
9 RI 
Ring 
indicator 
To 
DTE 
 
NOTE! A straight through cable should be used between the TANDBERG 3G Gateway’s RS-232 port and 
the DTE. 
The figure below illustrates the recommended cable-wiring scheme for connecting the 3G Gateway to a PC 
through RS-232. 
 
TANDBERG
 
3G
 
G
ATEWAY
 PC 
 
DCE, 9 pin 
DTE, 9 pin 
 
 1 CD  
  1 CD 
 2 RD  
  2 RD 
 3 TD  
  3 TD 
 4 DTR 
  4 DTR 
 5 GND 
  5 GND 
 6 DSR 
  6 DSR 
 7 RTS 
  7 RTS 
 8 CTS 
  8 CTS 
 9 RI  
  9 RI 
 
 
DTR and RTS are ignored. DSR, CD, and CTS are always asserted, while RI is not used.
 
2.2. 
Troubleshooting
 
D1320203       
                                                                                                                       4