Fast Ethernet Media Converter – Installation Guide
    
Installation 
 
The module comes equipped with a bank of DIP switches and 
jumpers for setting configuration.  
 
The default DIP switch settings (all switches in the UP position) 
and jumper settings will work for most installations.. 
 
The following steps are used to configure the Perle Fast 
Ethernet Media Converter Module:  
 
1.  Set the Auto-MDIX jumper (optional). 
2.  Set the Auto-Config jumper (CM-100 only) (optional) 
3.  Set the DIP switch settings (optional). 
4.  Insert the Media Converter Module into the chassis. 
5.  Connect the fiber cable. 
6.  Connect the copper cable. 
 
Auto-MDIX Jumper  
 
Note: The factory settings for Auto-MDIX will work for most 
installations, but if there is a need to modify the settings, follow 
the procedure below. 
The AUTO-MDIX jumper (J5) is located on the upper edge, at 
the midpoint of the module (see diagram below for labelling). By 
covering or strapping pins 1 and 2, the C-100 and CM-100 will 
operate as an MDI device. By covering or strapping pins 2 and 3, 
the C-100 and CM-100 will automatically detect the Ethernet 
cable’s polarity and configure itself as either an MDI or an MDIX 
device. Removing the strapping is the same as AUTO.  
NOTE: The default jumper setting is Auto