Cisco Systems 1105 用户手册
2-21
User Guide for the CiscoWorks 1105 Wireless LAN Solution Engine
78-14947-01
Chapter 2 Fault Monitoring
Notification Settings
Related Topics
•
•
•
Setting Trap Notification
This option allows you to enable the WLSE to send north-bound exception
notification to one or more SNMP trap receivers. The exception notification
contains information such as device name and IP, fault number, timestamp,
exception severity, and a message describing the problem.
notification to one or more SNMP trap receivers. The exception notification
contains information such as device name and IP, fault number, timestamp,
exception severity, and a message describing the problem.
The MIB that defines the trap and the varbinds can be found at the following URL:
ftp://ftp.cisco.com/pub/mibs/v2/CISCO-DEVICE-EXCEPTION-REPORTING-
MIB.my
ftp://ftp.cisco.com/pub/mibs/v2/CISCO-DEVICE-EXCEPTION-REPORTING-
MIB.my
Before You Begin
Make sure your SNMP trap receiver’s trap receiving daemon is set to the correct
port. The default port is set to 162.
port. The default port is set to 162.
Procedure
Step 1
Select Faults > Notification Settings. The Fault Notification Settings dialog box
appears.
appears.
Step 2
Select the message format for the notification: Plain Text or XML.
Step 3
Complete the following:
Field
Description
Trap
Select to enable trap notification.
Port
Enter the port number if different from the
default of 162.
default of 162.
Host
Enter the hostname/IP of the SNMP trap
receiver to which you want to send SNMP trap
notification.
receiver to which you want to send SNMP trap
notification.
Community
Enter the community string.