Debugger General Information
3-8
MVME166 Single Board Computer Installation Guide
3
Execute User Program
EXEC 
[ADDR] 
The EXEC command is used to initiate target code execution.  The specified 
address ("ADDR") is placed in the target Program Counter (PC).  Execution 
will start at the target PC address.  
Setup System Parameters
SETUP
 
Setup allows configuring certain parameters that are necessary for some I/O 
operations (SCSI, VME, and Ethernet).  When you execute this command, the 
default value is displayed, if any is available, and then you are prompted for 
input.  
The SETUP command VME parameters do not stay through a reset.  These 
parameters are not saved to NVRAM.  The remaining parameters (MPU Clock 
Speed, Ethernet Address, Local SCSI Identifier) are saved to NVRAM, but are 
not checksummed.  
166-Bug>setup 
MPU Clock Speed = "3300"? 
Ethernet Address = 000000000000? 
Local SCSI Identifier = "07"? 
VME Slave Enable [Y/N]                 = N? 
VME Slave Starting Address             = 00000000? 
VME Slave Ending Address               = 00000000? 
VME Slave Address Translation Address  = 00000000? 
VME Slave Address Translation Select   = 00000000? 
VME Slave Control                      = 0000? 
VME Master Enable [Y/N]                = Y? 
VME Master Starting Address            = 40000000? 
VME Master Ending Address              = 4FFFFFFF? 
VME Master Address Translation Address = 00000000? 
VME Master Address Translation Select  = 00000000? 
VME Master Control                     = 0D?