Debugger General Information
3-18
MVME166 Single Board Computer Installation Guide
3
To perform a disk operation, 166Bug must eventually present a particular disk 
controller module with a controller command packet which has been 
especially prepared for that type of controller module.  (This is accomplished 
in the respective controller driver module.)  A command packet for one type 
of controller module usually does not have the same format as a command 
packet for a different type of module.  The system call facilities which do disk 
I/O accept a generalized (controller-independent) packet format as an 
argument, and translate it into a controller-specific packet, which is then sent 
to the specified device.  Refer to the system call descriptions in the Debugging 
Package for Motorola 68K CISC CPUs User’s Manual
 for details on the format and 
construction of these standardized "user" packets.  
The packets which a controller module expects to be given vary from 
controller to controller.  The disk driver module for the particular hardware 
module (board) must take the standardized packet given to a trap function 
and create a new packet which is specifically tailored for the disk drive 
controller it is sent to.  Refer to documentation on the particular controller 
module for the format of its packets, and for using the IOC command.  
Default 166Bug Controller and Device Parameters
166Bug initializes the parameter tables for a default configuration of 
controllers and devices (refer to Appendix B).  If the system needs to be 
configured differently than this default configuration (for example, to use a 
70MB Winchester drive where the default is a 40MB Winchester drive), then 
these tables must be changed.  
There are three ways to change the parameter tables: 
Use BO or BH.  When you invoke one of these commands, the 
configuration area of the disk is read and the parameters corresponding to 
that device are rewritten according to the parameter information 
contained in the configuration area.  This is a temporary change.  If a cold-
start reset occurs, then the default parameter information is written back 
into the tables.  
Use the IOT.  You can use this command to reconfigure the parameter 
table manually for any controller and/or device that is different from the 
default.  This is also a temporary change and is overwritten if a cold-start 
reset occurs.  
Obtain the source.  You can then change the configuration files and rebuild 
166Bug so that it has different defaults.  Changes made to the defaults are 
permanent until changed again.