HSV Element Manager Event Codes
21
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
The HSV Element Manager is an application provided with the Storage Management 
Appliance that is used to configure and monitor HSV110 Array Controllers. The HSV 
Element Manager generates controller events and management agent events that help users 
understand the status of both the manager application and the storage elements. 
The Storage Management Appliance supports the HSV MIB version 2.0.
Controller Events
 shows events generated by the HSV Controller, which are logged in the Storage 
Management Appliance Event Log. The Software Component ID (SWC ID) and Event 
Number (Evt. No.) codes can be used to correlate events recorded in the Controller Event Log 
of the HSV Element Manager with the events logged in the Storage Management Appliance 
Event Log.
Table 8:  HSV Element Manager Event Codes: Controller Events
Event 
ID
Event 
Code
Sev-
erity
SWC 
ID
Evt. 
No.
Description
100
88030064
3
0
0
Storage Cell: %1  Event Code: %2  Description: recognized Controller event 
generated.
256
88030100
2
1
0
Storage Cell: %1  Event Code: %2  Description: During Executive Services 
initialization the system time value was set to the value contained in the time field. 
The action field contains one of the following codes which describes the condition 
that caused the time value to be: 0 = TOY clock unavailable; time reset to default 
date and time. 1 = TOY clock time value was less than or equal to the last known 
time value previously stored in nonvolatile memory; time reset to default date and 
time. 2 = EDC was bad for last known time value previously stored in nonvolatile 
memory; time reset to default date and time. 3 = TOY clock not running; time 
reset to default date and time. 4 = TOY clock time value believed to be accurate; 
time set to TOY clock time value. 
257
88030101
2
1
1
Storage Cell: %1  Event Code: %2  Description: The system time value was set to 
the value contained in the time field by a call to the EXEC$SET_TIME service. As 
part of setting the time in a dual HSV110 controller configuration, the times are 
synchronized.  The action field contains one of the following codes which 
describes the action taken: 0 = The time was set to the time value on this HSV110 
controller. 1 = The master HSV110 controller requested the slave HSV110 
controller to set it’s time to the time value. 2 = The slave HSV110 controller set the 
local time to the time value. 3 = The HSV110 controller’s TOY clock was set to the 
time value. 
768
88030300
2
3
0
Storage Cell: %1  Event Code: %2  Description: The HSV110 controller identified 
in the node_name field has failed in communicating with the Cabinet (Rack) Bus 
Interface Controller.
769
88030301
6
3
1
Storage Cell: %1  Event Code: %2  Description: The physical disk drive identified 
by the device field has been rendered inoperable. If the flags.quorum_disk flag is 
nonzero, the physical disk drive is the Storage System Quorum disk identified in 
the quorum_sequence field. If the flags.inq_state flag is nonzero, the content of 
the inq_data and capacity fields is valid. If the rss_flags.member_abnormal flag 
is nonzero, the content of the member_state field is valid. The rack_num field will 
not be valid until a future release.
770
88030302
3
3
2
Storage Cell: %1  Event Code: %2  Description: The physical disk drive identified 
in the node_name field will not be used because the maximum number of 