HP (Hewlett-Packard) hp OpenView storage management appliance software 用户手册

下载
页码 80
NetApp Filers Event Codes
9
Storage Management Appliance Software Event Code Definitions Application Notes
NetApp Filers Event Codes
The following events are generated by NetApp Filer devices and are recorded in the Storage 
Management Appliance Event Log. A number of these events are associated with user-defined 
traps and most indicate a condition that is likely to have a negative impact on operations. A 
small number of events mark a return to normal operation after some period of abnormal 
operation. 
The Storage Management Appliance supports the NetApp MIB version 1.2.
Table 4:  NetApp Filer Event Codes
Event ID
Event 
Code
Severity
Description
100
880E0064
2
An unknown trap event was received.
101
880E0065
3
A polling-style trap built by the user using the SNMP traps 
command on the filer.
102
880E0066
5
Disk Health Monitor reported a Disk Degraded-I/O Event.
103
880E0067
4
Disk Health Monitor reported a Disk Predictive-Failure Event.
104
880E0068
7
A user-defined trap indicating an extremely urgent situation, 
usually indicating that the system has failed and is shutting 
down.
105
880E0069
5
A user-defined trap indicating a condition that should be 
corrected immediately, such as a failed disk.
106
880E006A
6
A user-defined trap indicating a critical condition, such as a 
hard device error.
107
880E006B
5
A user-defined trap indicating an error condition, such as a 
mistake in a configuration file.
108
880E006C
4
A user-defined trap indicating a condition which is not an error, 
but which may require special handling.
109
880E006D
2
A user-defined trap meant to provide information, such as an 
hourly uptime message.
110
880E006E
1
A user-defined trap used for debugging purposes.
111
880E006F
7
System is shutting down because the system has been running 
in degraded mode for 24 hours.
112
880E0070
5
One or more disks failed.
113
880E0071
2
The failed disks have been repaired.
114
880E0072
7
Critical chassis or cpu fans have failed and the system is 
shutting down.
115
880E0073
5
One or more chassis fans failed.
116
880E0074
3
One or more chassis or cpu fans are in warning state.
117
880E0075
2
All fans are repaired.
118
880E0076
7
Critical power supplies or power rails failed and the system is 
shutting down.
119
880E0077
5
One or more redundant power supplies failed.
120
880E0078
3
One or more power supplies or power rails in warning state.
121
880E0079
2
Previously-failed power supplies or power rails have been 
repaired.
122
880E007A
4
CPU utilization exceeds 90 percent.
123
880E007B
2
CPU utilization has dropped back below 90 percent.