Perreaux Prisma 350 用户手册

下载
页码 38
 
 
34 
 
Power Consumption 
Idle................................................................................................................... 80W
M aximum .................................................................................................... 1300W
(at 4Ω rated output)
Mains Input Voltage 
100V, 110V, 120V, 220V, 230V or 240V AC at 50Hz or 60Hz 
(Set within the 350 at time of manufacture) 
Dimensions 
Width...............................................................................................430mm (16.9”)
Height ................................................................................................194mm (7.6”)
Depth...............................................................................................486mm (19.1”)
Fuse Ratings 
M ains input fuse
 
100 – 125V: ..........................................................................2SB slow blow 15A
200 – 250V: ..........................................................................2SB slow blow 10A
(user serviceable)
Internal DC rail fuses ...................................................4 x 2AG normal blow 10A
( NOT user serviceable)
Weight 
Net:..................................................................................................30.0kg (66.1lb)
Gross:...............................................................................................34.0kg (74.8lb)
Specifications 
Explained 
Rated Power Output 
(per cha nnel)
............................................ 350W
RMS 
into 8Ω
The  350  has  been  designed  around  the  industry  standard  8Ω  load.    The  350 
delivers  a  staggering  350W
RM S
  continuously  into  8Ω  loads  and  600W
RMS
  into 
4Ω  loads.   The  350  will  also  handle  complex  and  2Ω  loads  with stability  and 
ease. 
Frequency Response .................................................... 5Hz to 40kHz ±0.25dB
This is the “standard” specification with which everyone is familiar.  Actually, 
“frequency response” is a misnomer: technically, it should be called “amplitude 
response  versus  frequency”  for  it  describes  how  uniform  the  amplitude  or 
strength of signals of various frequencies is maintained.  It is generally thought 
that a difference of 1db is the least that can be perceived by ear.  To better that 
by a wide margin, the 350 is specified four times higher, thus far exceeding the 
audible range of the human ear. 
Total Harmonic Distortion 
(THD+N)
........................... 0.004%, @ 1kHz into 8Ω
M easurements  are  made  with  fixed,  purely  resistive  loads.    However,  since 
speakers are not purely resistive, an amplifier’s distortion specifications do not 
indicate what performance will be with the actual  loads presented by speakers.  
Perreaux  distortion  measurements  hold  for  any  conditions  presented  by  any 
known speaker.  Further, any measurable distortion in the Perreaux is second-
order harmonics – the least offensive to the ear.