Lennox Hearth EDVSTNM-B 用户手册

下载
页码 44
42
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 72
Figure 73
Step 9. Reassemble the remaining components 
by  reversing  the  procedures  outlined  in  the 
preceding steps.  
Use pipe joint compound or Teflon tape on all 
pipe fittings before installing (ensure propane 
resistant compounds are used in propane ap-
plications, do not use pipe joint compounds 
on flare fittings).
Step 10. Attach the conversion label provided 
in the conversion kit to the rating plate on the 
appliance. 
Step 11. Turn on gas supply and test for gas 
leaks.
ALWAYS TEST PRESSURE WITH THE VALVE 
REGULATOR  CONTROL  AT  THE  HIGHEST 
SETTING
B. Install the burner as shown in Figure 73
Ensure that the arm of the venturi of the burner 
is hooked onto the air shutter adjustment lever 
(refer to Figure 67 on page 41).The primary air 
opening can be adjusted by rotating the adjust-
ment lever from beneath the firebox floor. Refer 
to Figure 65 on page 36 for the recommended 
minimum primary air opening setting.
BURNER POSITIONING
PAN
BURNER
PILOT ASSEMBLY
Burner Orifice Sizes (all models)
Elevation
Feet (meters)
Natural
Gas
drill size (inches)
Propane
Gas
drill size (inches)
0-4500
(0-1372)
(0.125") 
*
21L81 •
#41 (0.096")
*
21L82 •
Table 9           
* Standard size installed at factory
                                        •  Part /Cat. Number