Whirlpool WGDH160UH 用户手册

下载
页码 16
9
3. Attach 
³⁄₄" PVC pipe to the condensate drain outlet. See 
“Location Requirements.”
4. Run the PVC pipe to an outdoor drain. Any horizontal run of 
drain pipe must have an anti-siphon vent for it to drain 
properly.
5. If needed, install a condensate pump kit (optional).
6. Using a 10" duct, attach the discharge air supply on the 
dehumidifier to the return air supply on the existing furnace or 
air handler. 
NOTE: Install ductwork in accordance with NFPA 90B 
Standard for the Installation of Warm Air Heating and Air 
Conditioning Systems (latest edition) and any local codes.
7. Attach the return air supply on the dehumidifier to the return 
air supply on the existing furnace or air handler near the 
return air grille.
NOTE: Do not draw air directly from the kitchen, bathroom, 
laundry room or unconditioned isolated basement.
8. Attach insulated flexible duct to the discharge air supply on 
the dehumidifier.
9. Run duct to the basement or crawl space of the building.
Horizontal Installation
Horizontal Installation with Added Return
A. Return air from house
B. Existing return air duct
C. To existing furnace or air handler
D. Backflow damper (required)
E. Dry air to crawl space or unconditioned isolated basement 
F. Manual damper (required)
G. Dehumidifier
H. Power damper (optional)
I. Outside air
J. Screened intake hood
A. Added return
B. Return air from house
C. Existing return air duct
D. To existing furnace or air handler
E. Back flow damper (required) 
F. Dry air to crawl space or unconditioned isolated basement 
G. Manual damper (required) 
H. Dehumidifier 
I. Power damper (optional)
J. Outside air
K. Screened intake hood