Waterford Appliances E63-NG1 用户手册

下载
页码 24
Waterford E63-1 EMERALD Freestanding Gas Stove
13
OPTIONAL REMOTE
CONTROL
Use the Waterford Remote Control Kit approved
for this unit. Use of other systems may void your
warranty.
The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.
1) Choose a convenient location on the wall to
install the receiver and the receptacle box
(protection from extreme heat is very im-
portant). Run wires from the fireplace to
that location, use Thermostat  Wire Table.
2) Connect the wires as per the wiring dia-
gram on page 14.
CAUTION
Do not connect the millivolt
remote control wires to the 120V
wires.
OPTIONAL WALL
THERMOSTAT
A wall thermostat may be installed if desired.
Connect the wires as per the wiring diagrams.
Note that the wires are  connected to the "TH"
on the gas valve. Use table below to determine
the maximum wire length:
Note: Preferable if the thermostat is in-
stalled on an interior wall.
Waterford offers an optional programmable
thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or
UL approved may be used.
CAUTION
Do not connect the millivolt
wall thermostat wires
to the 120V wires.
INSTALLATION
3) Attach the 4 grill clips with the 4 screws but
do not tighten down at this point.
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.
50 Ft.
32 Ft.
20 Ft.
12 Ft.
9 Ft.
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size                       Max. Length
Thermostat Wire Table
4) Place the grill into position on the front of the
door, center it in the front viewing area and
use the grill clips to hold it in place.
5) Tighten the screws on the grill clips.
6) Replace the glass and secure the glass
clips, reversing step 2)
7) Close the front door by reversing step 1).
The thermally activated safety switch
must be manually reset before first star-
tup.
TEST FOR FLUE
SPILLAGE
A "spillage" test must be made before the
installed unit is left with the customer. Follow
the procedure below:
1) Start all exhaust fans in the home and any
other gas appliances. Then close all doors
and windows.
2) Light the unit and set controls to maximum.
3) After five minutes, test that there is a "pull"
on the flue by placing a smoke match,
cigarette or similar device which gives off
smoke, on the edge of the draft hood. See
diagrams.
The smoke should be drawn into the draft hood.
If the smoke is not drawn into the draft hood,
turn the unit off and check for the cause of lack
of draft.
Note: If the flue is blocked or has a strong
reverse flow, the thermally actuat-
ed safety switch mounted in the
draft hood will automatically shut
off the gas supply within about 10
minutes.  If the heater turns off
because of this during the spillage
test, check for the