SCAN SPEED
Next Menu
Shutter speed
Auto
Auto focus mode
Auto
<Sharpness>
<White balance>
Prev (back to prev. menu)
Exit
Main Menu
<Camera>
<Line Sync>
<Power Up>
<Other>
EXIT
Main Menu
<Camera>
<Line Sync>
<Power Up>
<Other>
EXIT
Camera Menu
Backlight comp
Off
Reset camera
<Gain/AGC>
<Auto-iris>
<Next>
Exit
Other Menu
Auto flip
On
Limit stops
On
Park time minutes
0
Scan speed deg/s
25
Exit
The scan speed is adjustable from 1-40 degrees per second. This occurs in three scan
modes: auto, random, and frame scan.
To change the scan speed:
1.
Program preset 95 (28). The main menu appears.
2.
Position the cursor (>) beside Other.
3.
Press the Iris Open button to enter the Other menu.
4.
Position the cursor (>) beside Scan Speed deg/s.
5.
Press the Iris Open button. The cursor moves to the right, beside the number of degrees.
6.
Move the joystick up or down to toggle through the number of degrees (1-40) until you
reach the number you want. (If set on a low number, the scan will appear to barely
move but is still functioning.)
7.
SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
SHARPNESS
Sharpness Menu
Sharpness
5
Exit
Do the following to manually adjust the sharpness of the picture:
1. Program preset 95 (28). The main menu appears.
2. Position the cursor (>) beside Camera.
3. Press the Iris Open button to enter the Camera menu.
4. Position the cursor (>) beside Next.
5. Press the Iris Open button to go to the Next menu.
6. Position the cursor (>) beside Sharpness.
7. Press the Iris Open button to enter the Sharpness menu.
8. Press the Iris Open button. The cursor moves to the right, beside the sharpness value.
9. Move the joystick up or down to toggle through the available sharpness values. As the
numeric value changes, the sharpness of the picture on the monitor changes.
10. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.