Honeywell VISTA-250BP 用户手册

下载
页码 80
 
 
– 73 – 
Summary Of Audible Notification 
(Alpha Display Keypads) 
SOUND CAUSE 
DISPLAY 
LOUD, 
INTERRUPTED* 
  Keypad & External 
FIRE ALARM
 
FIRE is displayed; descriptor of zone in alarm is 
displayed.
 
LOUD, 
CONTINUOUS* 
  Keypad & External 
BURGLARY/AUDIBLE EMERGENCY 
ALARM  
ALARM  is displayed; descriptor of zone in alarm is 
also displayed. 
ONE SHORT BEEP 
 (not 
repeated) 
Keypad only 
a. SYSTEM DISARM   
b. SYSTEM ARMING  ATTEMPT 
WITH AN OPEN ZONE. 
c. BYPASS VERIFY  
a. DISARMED/READY TO ARM is displayed.  
b. The number and descriptor of the open protection 
zone is displayed. 
c.  Numbers and descriptors of the bypassed 
protection zones are displayed (One beep is heard 
for each zone displayed). Subsequently, the 
following is displayed: DISARMED BYPASS Ready 
to Arm
 
ONE SHORT BEEP 
  (once every 15 
sec.) Keypad only 
SYSTEM IS IN TEST MODE 
Opened Zone identifications will appear. 
TWO SHORT BEEPS 
  (once every 5 sec.) 
Keypad only 
SYSTEM IS ABOUT TO 
AUTOMATICALLY EXIT TEST 
MODE 
Opened Zone identifications will appear. 
ONE BEEP 
  (every 60 sec.)  
Keypad only 
LOW BATTERY AT A TRANSMITTER 
LO BAT displayed with description of transmitter. 
TWO SHORT BEEPS  
 Keypad 
only 
 
ARM AWAY OR MAXIMUM     
ARMED AWAY or ARMED MAXIMUM is displayed. 
Red ARMED indicator is lit. 
THREE SHORT 
BEEPS 
 Keypad 
only 
a. ARM STAY OR INSTANT   
b. ZONE OPENED WHILE SYSTEM 
IS IN CHIME MODE.   
c. ENTRY WARNING** 
a. ARMED STAY ZONE BYPASSED or ARMED 
INSTANT ZONE BYPASSED is displayed. Red 
ARMED indicator is lit. 
b. CHIME displayed, descriptor of open protection 
zone will be displayed if the [
4] key is pressed. 
c.  DISARM SYSTEM OR ALARM WILL OCCUR is 
displayed. 
RAPID BEEPING  
 Keypad 
only 
a. TROUBLE   
b. AC POWER LOSS ALERT*** 
c.  MEMORY OF ALARM  
a. CHECK displayed.  Descriptor of troubled protection 
zone is displayed. 
b. AC LOSS displayed (may alternate with other display
that may be present). 
c.  FIRE or ALARM is displayed; descriptor of zone in 
alarm is displayed.  
SLOW BEEPING  
 Keypad 
only 
a. ENTRY DELAY WARNING**  
b. EXIT DELAY WARNING  
 (if 
programmed) 
a. DISARM SYSTEM OR ALARM WILL OCCUR is 
displayed. Exceeding the delay time without 
disarming causes alarm.  
b. ARMED AWAY or ARMED MAXIMUM is displayed 
along with You May Exit Now 
If bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.  
** 
Entry warning may consist of three short beeps or slow continuous beeping, as programmed by your installer. 
***  Loss of system battery power is not indicated or annunciated by the keypad (warnings are for loss of AC power 
only).