Honeywell 5800ZBRIDGE 用户手册

下载
页码 4
800-08932  5/11  Rev. A 
- 1 - 
 
5800ZBRIDGE 
Z-Bridge Module
    
INSTALLATION AND SETUP GUIDE 
 
GENERAL INFORMATION 
5800ZBRIDGE  is  a  wireless,  intelligent  energy 
management  device  that  provides  an  interface 
between  Z-Wave  Modules  and  Honeywell  LYNX 
Security Systems  and VISTA  Control Panels  that  are 
equipped with RF keypads. 
Note: The 5800ZBridge is not compatible with the 5800TM or 
5883H modules. 
Features 
• 
Automatically set back Z-Wave enabled 
thermostat when security system is Armed 
AWAY. 
• 
Automatically turns lights off when security 
system is Armed AWAY. 
• 
Sends run command to Z-Wave enabled 
thermostat when security system is Disarmed. 
• 
Automatically turns lights on when security 
system is Disarmed. 
• 
Alarm Status light: Ready, Armed Away and Stay. 
• 
Will function with any Z-Wave device 
MOUNTING  
1.
  Determine the optimum mounting location taking 
care to avoid damp locations. To maximize the 
transmitter’s range, avoid mounting the device to 
metal objects, if possible. The module should be 
located a maximum of 6 feet from an unswitched 
120VAC outlet. 
2.
  Open the 5800ZBRIDGE case as shown in Figure 
1. 
3.
  Mount the 5800ZBRIDGE using the provided 
screws. (Refer to Figure 2) 
 
5800Z-002-V0
 
Figure 1. Opening the 5800ZBRIDGE 
POWER UP MODULE 
1.  Plug in 12VDC power supply, LED flashes 
ORANGE 3 times and then goes out. (Refer to 
Figure 2) 
PROGRAMMING 
Enroll 5800TM Code into Module 
1.  Press SW5 LEARN switch for 1 second and 
release. LED will begin flashing ORANGE. 
2.  Disarm or Arm the control panel (with 5800TM 
code turned on). The LED will stop flashing 
ORANGE and the color will follow status of the 
control panel. 
Note: The module will time out of program mode after 3 
minutes if no TM code is enrolled. 
 
Table 1 - 5800ZBRIDGE LED Indications  
Indication 
Meaning 
Flashing Red 
Armed AWAY 
Steady Red 
Armed STAY 
Solid Green 
Ready 
Flashing Orange 
ALARM/Panic 
Note:   Following an alarm, the User Code must be entered 
twice and the keypad must go to ready in order for the 
Z-Bridge Module to release thermostat setback and/or 
turn on lights. 
Enroll (include) Devices in Z-Wave Modules into 
5800ZBRIDGE module 
1.  Press the corresponding switch (SW1 through 4) 
for 1 second and release for any combination of 
four Thermostats or Lights. (Refer to Figure 2) 
2.
  The 5800ZBRIDGE LED will begin flashing 
Green. 
3.
  Press button on the respective Z-Wave device to 
learn (include) the device. The 5800ZBRIDGE 
LED will stop flashing GREEN and return to 
status of control panel.  
4.  Repeat for each Z-Wave device as applicable. 
Note: The module will time out of program mode after 2 
minutes if no Z-Wave device in enrolled (included). 
Reset 5800ZBRIDGE Module 
1.
  Disconnect the 12VDC power supply. 
2.
  Press and hold SW5 LEARN switch and then plug 
in 12VDC power supply. LED flashes Orange 5 
times and then goes out. 
3.
  Release switch SW5.  TM code has been deleted 
and 5800ZBRIDGE has been deleted (excluded) 
from the Z-Wave network.