Konica Minolta VIVID 700 用户手册

下载
页码 270
52
Chapter 
2
File
Menu
910
File – Import – Digitizer – One Scan (When VIVID 910 is Selected)
7
  Click on the [Scan] button to acquire 
the first scan data.
A scan will start, and a color image will be 
displayed in the Work window area.
M
emo
If [Use Color] is not checked (i.e. no check mark is 
shown), the scan data has no color image data, and a gray-
scale image will be displayed instead of a color image.
•  Clicking on the following radio buttons will 
make a change to the image displayed in the work 
window. The data acquired during the scan will 
remain unchanged.
Item
Explanation
[Mono] radio 
button
The current image is displayed in 
monochrome.
[Color] radio 
button
The color image acquired from 
the scan is displayed.
[Pitch] radio 
button
The distance data is displayed 
in the color that is shown in the 
Near-Far color slide bar ac-
cording to the distance from the 
object to the digitizer.
•  Clicking the [Color Read] button will re-scan for 
the color data only. The distance data will not be 
updated.
•  Clicking the [Edit] button enables you to delete 
the area that is not necessary for three-dimen-
sionalization by specifying it using the mouse. 
Messages will appear at the bottom of the Work 
window area as shown right, so follow them to 
operate the mouse.
   Check the [Edit] button again to exit the edit mode.
•  Switch to pitch display screen, and right-click on 
desired position in the screen while holding down 
[CTRL] key. The Z-axis coordinates at that posi-
tion (distance from VIVID 9i) will appear.
   To specify distance manually and perform mea-
surement, this value must be used.