DC Power Supply Precautions 
The following precautions must be observed when installing the chassis model with 
an internal DC power supply. 
1.  Check nameplate ratings to ensure there is no overloading of supply circuits that 
could effect overcurrent protection and supply wiring.  
2.  In addition, the following must be observed:  
a.  Connect the equipment to a 35 to 50 VDC power source that is electrically 
isolated from the alternating current source.  The 35 to 50 VDC power 
source is connected to a SELV DC source. 
 
b.  Route input wiring to terminal block and secure in such a manner that it is 
protected from damage and stress.  Do not route wiring past sharp edges or 
moving parts. 
 
c.  Incorporate a readily accessible disconnect device, with a 3mm minimum 
contact gap in the fixed wiring. 
 
3.  Reliable Earthing of this equipment must be maintained.  Particular attention 
should be given to supply connections when connecting to power strips, rather 
than direct connections to the branch circuit.   
IMC Networks Technical Support 
 Tel:   (949) 465-3000 or (800) 624-1070 (in the U.S. and Canada); 
  
+32-16-550880 