fiber was turned to forced mode, and “Off” for 
auto-negotiation mode. 
 
Note: Be sure the opposite end is using the same setting(forced or Auto-negotiation). 
And when using two converters at the same time, the two converters MUST set to 
forced mode. 
Switch 2: LLR 
    When the switch was turned to “On”, it means that the 
LLR was enabled and “Off” for disabled. 
 
Note: When using two converters at the same time, then only one converter need to 
enable the LLR function.
 
S
PECIFICATIONS
 
Standards: 
IEEE802.3ab 1000BASE-TX 
IEEE802.3z 1000BASE-SX/LX 
Data Transfer 
Rate: 
1488000pps for 1000Mbps 
Duplex Mode: 
Full Duplex Mode 
LED indicators: 
PWR, LNK/ACT 
Media Interface: 
RJ-45, SC 
EMI 
Compatiblity: 
FCC Class B 
CE Certification, Class B 
VCCI Class B 
Temperture: 
Storage: -10
°C ~ 70°C 
Operating: 0
°C ~ 40°C 
Humidity: 
10% ~90% non-condensing 
Power 
Consumption: 
5.5 Watts (maximum)