Philips P89LPC902 用户手册

下载
页码 114
Philips Semiconductors
User’s Manual - Preliminary -
P89LPC901/902/903
FLASH PROGRAM MEMORY
2003 Dec 8     
95
Figure 14-1: Flash Memory Control Register
Figure 14-2: Assembly language routine to erase/program all or part of a page
FMCON
Address: E4h
Not bit addressable
Reset Source(s): Any reset
Reset Value: 
BIT
SYMBOL
FUNCTION
FMCON.7-4
-
Reserved.
FMCON.3
HVA
Set if either an interrupt or a brown-out is detected during a program or erase cycle.  Also 
set if  the brown-out detector is disabled at the start of a program or erase cycle.
FMCON.2
HVE
High voltage error. Set when an error occurs in the high voltage generator. 
FMCON.1
SV
Security violation. Set when an attempt is made to program, erase, or CRC a secured 
sector or page.
FMCON.0
OI
Operation interrupted. Set when cycle aborted due to an interrupt or reset.
7
6
5
4
3
2
1
0
-
-
-
-
HVA
HVE
SV
OI
;* 
Inputs: 
       
 
;* 
R3 = number of bytes to program (byte) 
  * 
;* 
R4 = page address MSB(byte) 
 
 
  * 
;* 
R5 = page address LSB(byte) 
 
 
  * 
;* 
R7 = pointer to data buffer in RAM(byte)    * 
;* 
Outputs: 
       
 
;* 
R7 = status (byte) 
 
 
 
  * 
;* 
 C = clear on no error, set on error 
  * 
 
LOAD EQU  00H 
EP EQU 
68H 
 
PGM_USER:  
 
MOV 
FMCON,#LOAD  
;load command, clears page register 
 
MOV FMADRH,R4  
;get 
high 
address 
 
MOV FMADRL,R5  
;get 
low 
address 
 MOV 
A,R7 
  ; 
 MOV 
R0,A 
  ;get 
pointer 
into 
R0 
LOAD_PAGE: 
 
MOV 
FMDAT,@R0 
 
;write data to page register 
 INC 
R0 
  ;point 
to 
next 
byte 
 
DJNZ  R3,LOAD_PAGE 
;do until count is zero 
 
MOV 
FMCON,#EP 
 
;else erase & program the page 
 
 
MOV 
R7,FMCON 
 
;copy status for return  
 MOV 
A,R7 
  ;read 
status 
 
ANL 
A,#0FH 
 
;save only four lower bits 
 JNZ 
BAD 
  ; 
 
CLR 
 
 
;clear error flag if good 
 RET 
   ;and 
return 
BAD: 
 SETB 
  ;set 
error 
flag 
 RET 
   ;and 