Vidikron VP-6000a 用户指南

下载
页码 84
54
Vidikron PlasmaView Owner’s Operating Manual
PRE
L
IMINAR
Y
Table 6-1 lists the PlasmaView serial command set. Except where indicated, adjustments 
made using serial commands are stored in the same memory as those made in Installer 
Adjust mode. 
Table 6-1. Serial Commands 
Command
Value Range
Description
ASCII
HEX
Minimum
Maximum
Power
POF
50 4F 46
Power OFF. 
PON
50 4F 4E
Power ON. 
Input Select (Note 1)
IN1
49 4E 31
Switches the main screen to INPUT1.
IN2
49 4E 32
Switches the main screen to INPUT2.
IN3
49 4E 33
Switches the main screen to INPUT3.
IN4
49 4E 34
Switches the main screen to INPUT4.
IN5
49 4E 35
Switches the main screen to INPUT5.
INPS01
49 4E 50 53 30 31
Switches the main screen to INPUT1.
INPS02
49 4E 50 53 30 32
Switches the main screen to INPUT2.
INPS03
49 4E 50 53 30 33
Switches the main screen to INPUT3.
INPS04
49 4E 50 53 30 34
Switches the main screen to INPUT4.
INPS05
49 4E 50 53 30 35
Switches the main screen to INPUT5.
SSIS01
53 53 49 53 30 31
Switches the sub screen to INPUT1.
SSIS02
53 53 49 53 30 32
Switches the sub screen to INPUT2.
SWM
53 57 4D
Outputs main input to the full screen. 
SWS
53 57 53
Outputs sub input to the full screen. 
Aspect Ratio
AST
41 53 54
Executes AUTO SETUP on Input 1. 
SZMS00
53 5A 4D 53 30 30
Sets the aspect ratio to PIX by PIX.
SZMS01
53 5A 4D 53 30 31
Sets the aspect ratio to Standard 4:3.
SZMS02
53 5A 4D 53 30 32
Sets the aspect ratio to ANAMORPHIC 
16:9. 
SZMS03
53 5A 4D 53 30 33
Sets the aspect ratio to LETTERBOX.
SZMS05
53 5A 4D 53 30 35
Sets the aspect ratio to INTELLIWIDE.
Notes: 
1. When making input-specific adjustments such as to image quality, screen position/size or audio 
sub-volume, select the input you wish to affect before making such adjustments. 
2. These settings are not stored in memory.