Vidikron VP-5000a 用户指南

下载
页码 84
Vidikron PlasmaView Owner’s Operating Manual
53 
PRE
L
IMINAR
Y
6.1 
RS-232 Connection and 
Port Configuration
To interface the PlasmaView with a home theater automation/control system or a PC running 
terminal emulation software, connect it to your control system or PC as shown in Figure 3-13. 
Configure the RS-232 controller or PC serial port as follows: no parity, 8 data bits, 1 stop bit 
and no flow control. Set its baud rate to 115200, to match that of the PlasmaView RS-232 
port. 
On the PlasmaView, confirm that the Baud Rate is set to 9600BPS and that the ID Number is 
set to 01. These settings are found in the Option menu in Installer Adjust mode (refer to 
Option (Installer Adjust Mode) on page 43). 
6.2 
Serial Command Syntax
Serial commands to the PlasmaView take the following form:
• You can send commands in either hexadecimal or ASCII format. 
• ASCII commands are not case-sensitive. 
• Commands begin with the “Start of Text” (STX) character (02h or <Ctrl> B in ASCII), 
followed by the display ID (2 bytes), the command data and command argument (3 or 6 
bytes; refer to Table 6-1) and the “End of Text” (ETX) character (03h or <Ctrl> C in ASCII).
• You do not need to send a carriage return after the command. 
• The default PlasmaView display ID is 01 (30h 31h). With most commands, you can also use 
the “wildcard” display ID of “**” (2Ah 2Ah) in place of any value for the ID. However, when 
requesting status via serial commands, you must use a specific display ID; “**” does not 
work in these cases. 
Example
For example, if the PlasmaView ID number is set to its default value (01 = 30h 31h), send the 
following sequence to set the contrast to its highest possible level (255):  
6
Serial Communications
Avoid sending excessive status requests (also known as “polls”) to the 
PlasmaView. Doing so may delay command execution or prevent a 
command from being executed at all. As a general rule, limit status 
requests to once every five seconds or only as needed to refresh a control 
system display. 
Caution
STX
ID (2 bytes)
Command (3 bytes)
Argument (3 bytes)
ETX
Hex
02
30 31
or
2A 2A
43 4E 54
32 35 35
03
ASCII
<Ctrl>
 B
0 1
or
* *
C   N   T
2   5   5
<Ctrl>
 C