247 
 
5.12 Digital Monitor Power 
Management 
 
 
DMPM is monitor power management applied over the digital DVI interface. TANDBERG 
supports DMPM in software F2 and above. Six monitor power states are defined. 
 
Monitor On Power state: Transmitter (TANDBERG codec) and receiver (Monitor) are powered 
and active. This power state is equivalent with the DPMS normal mode. 
 
Intermediate Power state: When the codec goes from active to standby, it turns off the DVI 
transmitter and the monitor can go from Monitor On  
 
Power state to Intermediate Power state. 
 
Active-off Power state:
 The monitor can go from Intermediate Power state to Active-off Power 
state when the monitor timer expires. 
 
Non-Link Recoverable Off Power State: The monitor can enter Non-Link Recoverable Off 
Power State when the codec is switched off or if the DVI cable is disconnected. This power state 
is equivalent to the DPMS 
Off (with no DPMS recovery)
 state. 
 
Monitor Power Switch Off Power state: This state can be entered when the power switch on 
the monitor is toggled to its off position. This state has two sub-states dependent on if the codec 
is switched on or off.