Vidikron PlasmaView Owner’s Operating Manual
PRE
L
IMINAR
Y
Color Chart (Installer Adjust mode): Select Color Chart from the Picture menu to adjust the 
color density for each of the six primary colors: red, yellow, green, cyan, blue and magenta. 
Changing these settings for a primary color alters the hue of that color and affects the gamut 
(range) of possible colors. For example, changing the value for red moves the color closer to 
either yellow or magenta, which in turn affects all displayed colors having a red component.
To reset the color gamut settings to the factory default values, select C. Chart Reset. Then, 
press 
 to highlight YES and press SET
Select Return to exit the Color Chart menu. 
Gamma (Installer Adjust mode): The Gamma control determines how gray shades are 
displayed between minimum input (black) and maximum input (white) for all signals. A good 
gamma setting helps to optimize blacks and whites while ensuring smooth transitions for 
the “in-between” values utilized in other grays.
Unlike brightness and contrast controls, Gamma allows you to lighten or darken the overall 
tone of your images without changing the extremes. All images will be more vibrant while 
still showing good detail in dark areas.
The default Gamma setting of 2.2 is appropriate for most typical home theater environments.
Factory: To reset all picture quality settings for the current input to the default, 
installer-adjusted values (or factory defaults, if in Installer Adjust mode), select Factory from 
the Picture menu. Then, press 
 to highlight YES and press SET
Screen
Image Position: Use the up- or down-arrow buttons ( 
 ) to highlight Image Position
Then, press SET and use the left- and right-arrow buttons ( 
 ) to shift the image 
horizontally; use the up- or down-arrow buttons ( 
 ) to shift the image vertically.
V Shift (Installer Adjust mode): Use the up- or down-arrow buttons ( 
 ) to highlight 
Shift. Then, press SET and use the right-arrow button ( 
 ) to shift the image up; use the 
left-arrow button ( 
 ) to shift the image down.
H Shift (Installer Adjust mode): Use the up- or down-arrow buttons ( 
 ) to highlight 
Shift. Then, press SET and use the right-arrow button ( 
 ) to shift the image to the right; use 
the left-arrow button ( 
 ) to shift the image to the left. 
Frequency Adjust (Input 1 only): Use the up- or down-arrow buttons ( 
 ) to highlight 
Freq. Adj. Then, press SET. The Frequency Adjust control adjusts the PlasmaView’s internal 
clock frequency in small increments to match that of the incoming signal. Use it to reduce or 
eliminate letter breakup, flickering or other “noise” in a computer screen image. 
Phase Adjust (Input 1 only): Use the up- or down-arrow buttons ( 
 ) to highlight 
Phase Adj. Then, press SET. Use the Phase Adjust control to correct color misalignment or 
flickering text in a computer screen image. 
H-Size (Installer Adjust mode): Use the up- or down-arrow buttons ( 
 ) to highlight 
H-Size. Then, press SET and use the right-arrow button ( 
 ) to increase the width; use the 
left-arrow button ( 
 ) to decrease it. 
COLOR CHART
RED : 
+30
YELLOW : 
+
30
GREEN : 
+
30
CYAN : 
+
30
BLUE : 
+
30
MAGENTA : 
+
30
C. CHART RESET
    RETURN
 
ENTER
SET
EXIT
MENU
INPUT 1
PLASMAVIEW
SCREEN
SET-UP
OPTION
PICTURE
SET
SET
EXIT
MENU
:  0 /   0
:  0
:  0
IMAGE POSITION
FREQ. ADJ.
PHASE. ADJ.
IMAGE RESET
INPUT 1
INSTALLER ADJ.
SCREEN
SET-UP
OPTION
PICTURE
SET
SET
EXIT
MENU
:  +128
:  +128
:  +128
:      +4
:        0
:        0
H SHIFT
V SHIFT
FREQ. ADJ.
PHASE ADJ.
H-SIZE
V-SIZE
IMAGE RESET
Frequency Adjust and Phase Adjust are adjustable only when Auto Setup 
Mode
 (in the Option menu, described later in this section) is set to OFF. 
Note