Aiphone IS 用户手册

下载
页码 28
8
Cables
Cables and connectors are not included with the products.
Refer to page 9 to 26 for details about each unit connection.
Notes on cables
 
Pair4
Pair3
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Pair2
Pair1
T568A
Pair4
Pair2
Pair3
Pair1
T568B
How to connect or disconnect stranded wires.
8mm
(3/8")
Notes on CAT5e/6 cables
Do not bend the cables to an extent where the radius is 
• 
less than 25 mm (1”). Communication failure could result.
Do not remove the CAT5e/6 cable jacket more than 
• 
necessary.
Odd number cables, such as 
• 
three conductor wire, cannot be 
used.
Unless otherwise noted, never use individual 
• 
conductors, twisted pair cable or coaxial cable.
CAT5e/6 cable
25mm (1") or more
Less than 25mm (1") 
CAT5e/6 cable
Arrange the color code of the RJ45 connections in accordance 
• 
with EIA/TIA-568A or 568B.
Be sure to check the condition of cable connections with a 
• 
LAN checker before connecting with a LAN cable.
An RJ45 connector with a cover cannot be connected to the 
• 
port for CAT5e/6 on master stations, door stations, or room sub 
stations. Use a cable without a cover for the units except for the 
control units.
Do not pull or put excess strain on CAT5e/6 cables.
• 
Use a straight-through cable for connecting units. Use a 
• 
crossover cable when connecting with a PC directly.
Strip off the cable jacket by following the indication 
on each unit.
e.g.) IS-MV (back)
Release button
Twist the strands together, then insert the 
• 
wire into one of the quick coupling terminals.
To ensure that the wire won't bend, press the release button while inserting into terminal.
• 
e.g.) IS-CCU
e.g.) IS-CCU
Release button