16-Channel Digital Video Recorder 
 
33 
 
 
 
 
Figure 40 — Health Check screen 
The DVR can be configured to run self-diagnostics and report 
the results. 
 
Highlighting the box beside System and pressing the   button 
allows you to select the interval that you want the DVR to run 
self-diagnostics on the system.  You can select from 1 hr. to 
30 days or Never. 
 
Highlight the Setup... box beside Check Recording and press the   
button.  The Check Recording screen appears. 
 
Highlighting Schedule On and pressing the   button toggles On and 
Off.  When set to On, you can select the day, time range and interval that 
you want the DVR to run self-diagnostics on the recorder.  The Interval 
can be selectable from 1 min. to 7 days or Never.  The   box allows 
you to delete a check recording schedule. 
 
Highlighting the box under the Interval heading beside each alarm-in and pressing the   button allows you to change 
the interval that you want the DVR to run self-diagnostics on Alarm Inputs.  You can select from 1 hr. to 30 days or Never. 
 
 
 
Highlight the Storage tab, and the Storage screen displays. 
 
 
 
Figure 41 — Storage screen. 
Highlight the box beside Disk Bad Notify, and press the   
button.  Select percentage level of bad disk sectors at which 
you want the DVR to trigger an alert.  Percentage levels range 
from 10% to 90%. 
 
Highlight the box beside Disk Almost Full Notify, and press 
the   button.  Select the percentage level of disk usage at 
which you want the DVR to trigger an alert.  Percentage levels 
range from 80% to 99%. 
 
Highlight the first box beside Disk Temperature, and press 
the   button.  Use the Up and Down arrow buttons to scroll 
through the numbers.  Refer to the hard disk drive 
manufacturer’s documentation for the correct temperature 
setting.  If the temperature of hard disk drive exceeds the 
defined threshold, the system triggers an alert. 
 
Highlight the second box beside Disk Temperature, and press the   button.  Select either ºF (Fahrenheit) or ºC 
(Celsius), and press the   button. 
 
 
 
Highlight the Actions tab, and the System Event Actions screen displays.