Attendant Backup
change console-parameters
On Page 1 of this form, administer the following Attendant Backup 
parameters:
The 
Calls in Queue Warning
 level should be set to 1 if the 
customer uses the backup voice terminals for most call handling. If 
the customer uses the attendant console, you can set this level to 
a higher threshold.
The 
Ext Alert Port (TAAS)
 field must have an analog circuit 
equipment location administered even if you do not have external 
ringing equipment connected to the circuit. This is required to 
allow the Attendant Backup feature to work properly.
The 
No Answer Timeout
 controls when ringing at the console 
will stop after a call is waiting in queue. When the timeout occurs, 
the console stops ringing, but the call can still be answered. A 
good value to begin with is 10.
The 
Alerting
 field controls the timeout limit before the console 
automatically goes into Night mode and Position Busy when calls 
are not answered. This is a good feature to administer in the situa-
tion where the attendant takes a break or leaves at the end of the 
day, and forgets to put the console into Night service. For exam-
ple, if the 
No Answer Timeout
 field is set to 10 seconds and the 
Alerting
 field is set to 10 seconds, the following occurs: a call 
rings at the console, after 10 seconds the console ringing shuts 
off, the call continues to queue for 10 seconds, then the console 
goes into Night mode and Position Busy. The call can now be 
answered from a backup voice terminal.