13
Capacitance 
Loading 
Table 
Use this table to match the capacitance loading characteristics of 
your SXV2 to that recommended by your cartridge manufacturer.  
Consult your cartridge documentation for the correct capacitance 
figure. 
If no capacitance value is recommended, use the lowest setting. 
 
C Load 
Dip Switch Setting 
(pF) 
27 
UP 
UP 
UP 
UP 
74 
DOWN 
UP 
UP 
UP 
127 
UP 
DOWN 
UP 
UP 
297 
UP 
UP 
DOWN 
UP 
417 
UP 
UP 
UP 
DOWN 
 
Note:  Remember  to  factor  in  tonearm  and  interconnect 
capacitance  of  your  turntable;  consult  your  turntable 
documentation for these values.  See example following for 
explanation. 
Gain Setting 
Table 
Use this table to configure the gain characteristics of your SXV2 
to  suit  the  output  voltage  of  the  cartridge  you  are  using,  where 
switch  in  UP  position  is  OFF  and  switch  in  DOWN  position  is 
ON. 
Consult your cartridge documentation for its rated output voltage.  
Set the gain configuration where the “Sensitivity” of your SXV2 
is  within  ±50%  of  your  cartridge  output  voltage.    If  no 
configuration  falls  into  this  bracket,  use  the  setting  with  the 
sensitivity higher than your cartridge output voltage. 
 
Gain 
Sensitivity 
Mode 
Dip Switch Setting 
(dB) 
(mV) 
 
10 
11 
40 
7.50 
MM 
UP 
DOWN 
50 
2.37 
MM 
DOWN 
DOWN 
60 
0.75 
MC 
UP 
UP 
70 
0.24 
MC 
DOWN 
UP 
 
Note:  If more than one setting falls within ±50% of your cartridge 
output  voltage,  the  lower  sensitivity  configuration  will 
result  in  greater  dynamic  range,  the  higher  will  be  less 
susceptible to clipping. 
Note:  Rated output is 0.75V
RMS
.
 
Sensitivity value measured at rated output. 
Gain measured at 1kHz.