Troubleshooting Guidelines
Error Messages
5-9
The names and values are displayed in the following order:
Error Messages
5
The 4600 Series IP Telephones issue messages in English only. The IP Telephones also display 
messages from the switch, which outside the United States may issue messages in the local 
language.
Table 5-2.  Parameter Values
Name
System Value
Format
Model
46ccDccc 
up to 8 ASCII graphics characters
Market
domestic 
export 
Only one value is displayed
Phone SN
cccccccccccc
cccccccc
 
Phone Serial Number, up to 18 ASCII graphic 
characters
PWB SN
cccccccccccc
cccccccc
 
Printed Wiring Board (circuit board) Serial Number, 
up to 18 ASCII graphic characters
PWB comcode
ccccccccc 
9 ASCII numbered characters
MAC address
00:60:1D:hh:hh:hh 
Each octet of the MAC address is displayed as a 
pair of hexadecimal numbers.
filename1.exe 
filename2.exe 
up to 16 ASCII graphic characters.
Out of the box, there will be only one 
filename.exe. After installation, there should be 
two filenames. If there is only one, installation has 
failed. Verify the problem, and then re-install the 
telephone.
Table 5-3.  Possible Error Messages During Installation or Operation of 4600 Series IP 
Telephones
Error Message
Cause/Resolution
During Installation 
Checksum error
CAUSE: Downloaded application file was not downloaded or 
saved correctly.
RESOLUTION: The telephone automatically resets and attempts 
to re-initialize.