SAFETY INSTRUCTION 
WARNING: Only competent service personnel may carry out work involving the testing or repair 
of this equipment. 
 
X-RAY RADIATION PRECAUTION 
 
1. 
Excessive high voltage can produce potentially hazardous X-RAY RADIATION. To avoid 
such hazards, the high voltage must not exceed the specified limit. The nominal value of the high 
voltage of this receiver is 25-26 KV (20”-21”) or  26 KV (25” - 28”) at max beam current. The high 
voltage must not, under any circumstances, exceed 27.5 KV (20”), 29KV (21”), 29.5 KV (25") or 
30 KV (28"). Each time a receiver requires servicing, the high voltage should be checked. It is 
important to use an accurate and reliable high voltage meter. 
2. 
The only source of X-RAY Radiation in this TV receiver is the picture tube. For continued 
X-RAY RADIATION protection, the replacement tube must be exactly the same type tube as 
specified in the parts list. 
 
SAFETY PRECAUTION 
 
Potentials of high voltage are present when this receiver is operating. Operation of the receiver 
outside the cabinet or with the back board removed involves a shock hazard from the receiver. 
Servicing should not be attempted by anyone who is not thoroughly familiar with the precautions 
necessary when working on high voltage equipment. 
Discharge the high potential of the picture tube before handling the tube. The picture tube is 
highly evacuated and if broken, glass fragments will be violently expelled. 
If any Fuse in this TV receiver is blown, replace it with the FUSE specified in the Replacement 
Parts List. 
When replacing a high wattage resistor (metal oxide film resistor) in the circuit board, keep the 
resistor 10 mm away from circuit board. 
Keep wires away from high voltage or high temperature components. 
This receiver must operate under AC 230 volts, 50 Hz. NEVER connect to a DC supply or any 
other voltage or frequency. 
 
PRODUCT SAFETY NOTICE 
 
Many electrical and mechanical parts in this equipment have special safety-related 
characteristics. These characteristics are often passed unnoticed by a visual inspection and the 
X-RAY RADIATION protection afforded by them cannot necessarily be obtained by using 
replacement components rated for higher voltage, wattage, etc. Replacement parts which have 
these special safety characteristics are identified in this manual and its supplements, electrical 
components having such features are identified by designated symbol on the parts list. Before 
replacing any of these components, read the parts list in this manual carefully. The use of 
substitutes replacement parts which do not have the same safety characteristics as specified in 
the parts list may create X-RAY Radiation.