Clarity WN=5230-S 用户手册

下载
页码 122
 
 
WN-5230-S VideoWall User’s Guide 
 
 
55 
 
 
Assign each display a unique address using the Unit 
ID knob.  Both the Group and Unit ID numbers are 
used 
The address of the display in the upper left corner (as 
seen from the front) must be zero. The addresses of 
the other displays must increase left to right, top 
bottom, increasing by one for each display. Therefore, 
the display in the lower right corner (as seen from the 
front) always has the highest address.  
00 01 
02 03 
2x2 example 
 
(Seen from the 
front) 
0 1  2 
3 4  5 
7.  Set each display’s address 
(See note below for walls 
larger than 4x4.) 
3x3 example 
6 7  8 
8.  Set the Wall Size on each 
display  
Open the Wall Processor menu. Enter the horizontal 
and vertical wall size. Each display’s menu should 
show the same horizontal and vertical wall size.  
Each display should show a different Current Unit 
value. This value represents its location in the wall.  
 
Note: Clarity’s Big Picture handles up to a 6x6 video wall. Because the Unit 
knob only has 16 positions, the Group knob must be used for all walls that 
have more than 16 displays. A 6x6 wall would be numbered like this (top 
number is Group; bottom number is Unit): 
00 01 02 03 04 05 
06 07 08 09 0A 0B 
0C 0D 0E 0F  10  11 
12 13 14 15 16 17 
18 19 1A 1B 1C 1D 
1E 1F 20 21 22 23