Chapter 2: Installation
13
Note: The above images are for illustration only and may not be the exact
representation of the Paragon components you purchased.
representation of the Paragon components you purchased.
The steps below correspond to the numbers in the above diagram.
1. Connect the power cord to the Main Unit.
2. (Optional) Connect a Stacking Unit if it is needed.
a. Connect the power cord to the Stacking Unit.
b. Connect one end of a stacking cable to the ʺExpansion Port Outʺ
on the back of the Stacking Unit. Connect the other end of the
cable to the ʺExpansion Portʺ on the Main Unit.
cable to the ʺExpansion Portʺ on the Main Unit.
Note: For P2‐UMT1664M and P2‐UMT1664S, you must use two
stacking cables. For detailed instructions, see Installing the Paragon
P2‐UMT1664S Stacking Unit (on page 35).
stacking cables. For detailed instructions, see Installing the Paragon
P2‐UMT1664S Stacking Unit (on page 35).
c. Power on all switching units.
d. On the front panel of the Main Unit:
Press the FUNC button and then use the and buttons to
select ʺStacking Support.ʺ Press the ENT button to confirm
the selection.
the selection.
Use the and buttons to set the total number of Stacking
Units desired (3 maximum for P2‐UMT832M or 1 maximum
for P2‐UMT1664M). Press the ENT button to save the setting.
for P2‐UMT1664M). Press the ENT button to save the setting.
e. On the front panel of the Stacking Unit:
Press the FUNC button and then use the and buttons to
select ʺSet Stack ID.ʺ Press the ENT button to confirm the
selection.
selection.
Use the and buttons to assign the Stacking Unit ID. (Each
Stacking Unit for P2‐UMT832M MUST HAVE A UNIQUE ID
[1‐3].) Press the ENT button to save the setting.
[1‐3].) Press the ENT button to save the setting.
f. Power OFF all switching units.
g. Power ON the Stacking Unit. (This must be done before
powering on the Main Unit.)
3. Power on the Main Unit.
4. Connect one end of a Cat 5 UTP cable to User Port #1 on the back of
the Main Unit. Connect the other end of the cable to the ʺCat5 Portʺ or
ʺParagon Portʺ on the back of the user station.
ʺParagon Portʺ on the back of the user station.
5. Connect a power cord to the user station and power it on.