B&B Electronics ESP902 用户手册

下载
页码 47
 
 
Server Properties Configuration 
Manual Documentation Number: ESP901-902-3704 
Chapter 5 
35 
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com 
B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com 
Flow Control  
The Flow Control setting must match the requirements of the serial 
device connected.  
N
N
o
o
t
t
e
e
:
:
 
 
 
 Select None when setting the port as RS-485 or 4-wire RS-422. 
TCP/UDP Protocol  
Select 
TCP
 (Transmission Control Protocol) or 
UDP
 (User Datagram 
Protocol) protocol. If the application does not require a UDP 
connection, select TCP. TCP guarantees reliable communication with 
error checking whereas UDP provides faster transmission. 
UDP Mode 
When UDP mode is chosen the 
Serial timeout
TCP alive timeout
Connection mode
Connection at
Max connection
 and 
Remote IP address
 fields are replaced with the following 
four fields: 
Destination IP address range
Port number
 and 
Source IP address range
. In this mode the server can be 
configured to broadcast data to and receive data from multiple 
IP addresses. Four IP address range fields are provided. 
 
Figure 32.  The Server UDP Configuration Screen 
Serial Timeout 
Default for the 
Timeout 
property is 0, or no timeout. Setting 
Timeout
 
to any value between 1 and 65535 seconds activates it. If 
Timeout
 is 
set to 5 seconds and the 
Serial Server
 is configured as a 
Server
, the 
Client
 makes a connection and communications starts. If 
Server Properties Configuration 
36 
Chapter 5 
Manual Documentation Number: ESP901-902-3704 
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com 
B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com 
communications are ideal for 5 seconds the 
Serial Server
 will reset and 
make itself available for another client connection. 
 
TCP Alive Timeout 
The 
Serial Server
 monitors TCP activity. If TCP activity stops for the 
length of time specified in this field the connection will be closed. This 
field can be set to any value between 0 and 255 minutes. If zero, or no 
value, is entered into this field the server will not disconnect. 
Connection Mode  
The Connection Mode field has three options: 
Server
Client
 and 
Client (no heartbeat). 
When 
Client
 or 
Client (no heartbeat)
 is 
selected 
the Connection at
 field automatically becomes active 
(allowing the user to select 
Power up
 or 
Data Arrival)
.  
•  When using the 
Virtual COM Port
 feature, select 
Server.
 
•  When using a 
TCP
 or 
UDP Socket
 program, select 
Server
•  When using 
Paired Mode
 communication between two serial 
servers set up one as a 
Client
 and the other as a 
Server
•  When connecting to a server that does not support 
Heartbeat
select 
Client (no Heartbeat).
 
Delimiter HEX 1 and Delimiter HEX 2 
These fields allow the user to enter two ASCII characters (in hex 
format) that delimit the beginning and end of a message. When a 
message with both these delimiters is received at the serial port, the 
data contained in the serial buffer is placed in an Ethernet packet and 
sent out the Ethernet port. If only Delimiter 1 is set (Delimiter 2 is zero 
or blank), upon receiving Delimiter 1 the ESP901/902 will put all the 
data in the serial buffer in an Ethernet packet and send it out the 
Ethernet port. If serial data greater than 1 kilobyte is received it will 
automatically be placed in an Ethernet packet and sent out the Ethernet 
port . 
Force Transmit 
This field allows the user to set a maximum time limit between 
transmissions of data. The value set in this field multiplied by 100 ms 
determines the Force Transmit time. When the elapsed time reaches the 
time configured in this field, the TCP/IP protocol will pack the data 
currently in the serial buffer into a packet and send it out the Ethernet 
port.