Planar EL640.480-AM 用户手册

下载
页码 21
 
EL640.480-AM Operations Manual (020-0351-00C) 
Specifications 
The EL panel is a matrix structure with column and row electrodes arranged in 
an X-Y formation. Light is emitted when an AC voltage of sufficient amplitude 
is applied at a row-column intersection. The display operation is based on the 
symmetric, line at a time data addressing scheme. Operating voltages required 
are provided by a DC/DC converter. 
Unless otherwise specified, performance characteristics are guaranteed when 
measured at 25°C. 
Power 
The supply voltages required for the displays are shown in Table 1. All internal 
high voltages are generated from display supply voltage (VH). The logic supply 
voltage (VL) should be present whenever video input signals or VH is applied.  
Table 1. DC Input Voltage Requirements. 
 
AM1, AM8 ETL
AM8 IN/ET 
Notes 
 
 
12 V 
24 V 
 
VL 
+5 V  
±5% 
  +5 V  
±5% 
  +5 V  
±5% 
absolute max 7.0 V 
VH 
+12 V 
±10% +12 
±10% +24 
±10%  absolute max. 15 V 
and 30 V 
respectively 
IL, max 
75 mA 
75 mA 
75 mA 
@ VL = +5 V 
IH, max 
2.0 A 
2.0 A 
1.0 A 
@ VH = +12 V 
Ptyp, 120 Hz 
11 W 
11 W 
11 W 
3840 'E' characters 
Pmax, 120 Hz 
24 W 
24 W 
24 W 
50/50 2x2 
checkerboard 
CAUTION: Absolute maximum ratings are those values beyond which 
damage to the device may occur. 
Table 2. Video Input Requirements. 
Description Min 
Max 
Notes 
Video logic high voltage 
3.7 V 
5.0 V 
All input thresholds are 
CMOS 
Video logic low voltage 
0 V 
0.9 V 
Video lines have 100 
Ω 
series resistors 
Video logic input current 
– 10 µA 
+10 µA 
 
There is no overcurrent protection on either the VH  or VL  inputs to protect 
against catastrophic faults. Planar recommends the use of a series fuse on the 
12 volt supply. A general guideline is to rate the fuse at 1.8 to 2 times the 
display maximum current rating.