PRE
L
IMINAR
Y
DHD
1.
Select Calibration -> Adjustment Mode 
and set it to Secondary.
2.
Select Service -> Test Video and choose 
Secondary Alignment.
Projector (Align Secondary Image with 
Screen)
1.
Align the image to the screen by 
adjusting the bottom primary lens 
zoom, focus and H/V offset.
2.
Tighten the bottom primary lens lock 
screw.
3.
Q-1500d/CineWide with 
AutoScope only: Remove 
anamorphic lenses.  
Set the 
AutoScope transport motor AC 
switch to the “on” position.
Note: The default warp is 46 pixels on 
the left and right sides (x) and 26 pixels at 
the top and bottom (y). If more is 
needed, use the “Image Alignment” 
controls to increase it.
DHD
1.
For a ceiling-mounted (inverted) and/or 
rear-projection installation, select 
Service -> Display Device -> 
Configure -> Installation -> 
Picture Orientation 
and set it as needed. 
2.
Select Aspect Ratio and set it to Cinema
On a Q-1500d/CineWide with AutoScope, 
this should position the anamorphic lens 
transport in front of the primary lenses. 
3.
Select Calibration -> Adjustment Mode 
and set it to Primary
4.
Select Service -> Test Video and choose 
Primary Alignment.
Projector
1.
(Re-)install anamorphic lenses.
2.
Align the primary image with the 
screen by adjusting the top 
anamorphic lens to produce the least 
amount of distortion.
DHD
1.
Select Calibration -> Adjustment Mode 
and set it to Secondary.
2.
Select Service -> Test Video and choose 
Secondary Alignment.
Projector
1.
Align the secondary image to the 
screen by adjusting the bottom 
anamorphic lens to produce the least 
amount of distortion.
DHD (Align Secondary Image with Primary 
Image)
1.
Select Aspect Ratio and set it to 16:9.
2.
Select Calibration -> Adjustment Mode 
and set it to Secondary.
3.
Select Calibration -> Image Alignment 
-> Corner Alignment
, check the Primary 
Test Pattern
 and Secondary Test 
Pattern 
boxes and adjust corners.
4.
Select Calibration -> Image Alignment 
-> Midpoint Alignment
, check the 
Primary Test Pattern and Secondary 
Test Pattern 
boxes and adjust midpoints.
Projector
No adjustment needed. 
Note: The Primary lens image is usually 
left un-warped. This provides the best 
image quality and will be un-scaled for 
1080p sources. You can adjust the 
Primary image if needed, however, by 
setting the Adjustment Mode to 
Primary, checking the Primary Test 
Pattern
 and Secondary Test Pattern 
boxes and adjusting the corners and/or 
midpoints prior to this step.
Table 3-6. Q-1500d Optical Alignment Procedure (with Anamorphic Lenses) (continued)