Q-1500d Series Installation/Operation Manual
43 
PRE
L
IMINAR
Y
Additional Connections to 
the Primary DHD 
Controller (Optional) 
The Primary DHD Controller provides the following interfaces to external equipment that 
allow it to control or be controlled by that equipment:
• An RS-232 interface to a PC or control/automation system;
• Three (3), 12-volt trigger outputs;
• An infrared (IR) repeater input;
• An Ethernet network interface for firmware updates and maintenance notifications.
The following sections describe how to make these interface connections. For more 
information about using these connections, refer to Network on page 88 anExternal 
Control 
on page 101.
RS-232 Controller Connection: Use a straight-through, 9-pin RS-232 cable to connect 
a PC or control/automation system (if present) to the RS-232 port on the Primary DHD 
Controller; see Figure 3-16. 
Figure 3-16. RS-232 Control System Connection to Primary DHD Controller
H
HDMI 4
HDMI 3
HDMI Out
Audio Only
HDMI Out
To Display
Ethernet
PC / Control
RS232
Display Control
IR
H
HDMI 4
HDMI 3
HDMI Out
Audio Only
HDMI Out
To Display
Ethernet
Display Control
IR
1
2
3
4
5
7
8
9
6
to Automation/
Control System
or PC
2 Receive Data
3 Transmit Data
5 Ground
(none of the other pins are used)