Runco Q-1500-D/Cinewide 用户手册

下载
页码 148
Q-1500d Series Installation/Operation Manual
51 
PRE
IMINAR
Y
3.8 
Power-Up Sequence 
and Optical Alignment 
Procedure
At this point you are ready to perform the initial power-up sequence and optical alignment 
procedure, which is summarized in Table 3-6 and described in detail in the sections that 
follow. 
This procedure assumes the following:
• You are installing a projector equipped with anamorphic lenses. (If not, you can skip 
those tasks relating to the anamorphic lenses.)
• You have already completed the physical installation of the projector, DHD Controllers 
and Brightness Acceleration Engine as described in the previous sections. If you have 
not, do so now.
• You have connected the various system components to each other, to external 
equipment and to AC power. If you have not, do so now. 
Table 3-6. Q-1500d Optical Alignment Procedure (with Anamorphic Lenses)
DHD
1.
Leave system off for now.
2.
Connect an active 1080p source to the 
HDMI 1 connector.
Projector
1.
Mount the projector (refer to 
Mounting the Q-1500d on 
page 36).
2.
Mount the DHD Controllers and 
Brightness Acceleration Engine (refer 
to Mounting the DHD Controllers 
and Brightness Acceleration 
Engine 
on page 37
).
3.
Connect system components to each 
other and to external equipment (refer 
to System Interconnections on 
page 38).
4.
Q-1500d/CineWide with 
AutoScope only: Install 
anamorphic lenses 
in retracted 
position (out of the light path) and 
ensure that the AutoScope transport 
motor AC switch is in the “off” 
position.
5.
Loosen the lock screw for both 
primary lenses.
Note: At this point the anamorphic 
lenses are simply used as weight to 
maintain the correct center of gravity 
while you adjust the primary lens, so that 
the projector won’t shift when you add 
the anamorphic lenses later.
DHD
1.
Turn on system and select the HDMI 1 
input.
2.
Select Calibration -> Adjustment Mode 
and set it to Primary
3.
Select Service -> Test Video and choose 
Primary Alignment
Projector (Align Primary Image with 
Screen)
1.
Adjust the ceiling mount to correct for 
image keystone and clocking.
2.
Align the image to the screen by 
adjusting the top primary lens zoom, 
focus and H/V offset.
3.
Tighten the top primary lens lock 
screw.
Notes: 
1.
You must enter a passcode to 
access the Calibration or Service 
menu.
2.
The lock screw locks all lens 
adjustments except for focus.
START