NCR 5972 用户手册

下载
页码 90
 
 
Chapter 5:  Service 
5-3 
 
Servicing the Display 
Warning: 
Before servicing the equipment plug your safety strap 
into a proper grounding outlet. Failure to do so could damage the 
equipment. 
Normal Operation 
On power‐up, the unit displays the firmware part number for 2 
seconds, then lights all pixels for 2 seconds, then goes blank and awaits 
commands from the host. 
Troubleshooting Procedures 
The NCR 5972 Customer Display requires minimal maintenance. 
Should the display malfunction, adhere to the procedures in the 
following troubleshooting chart. 
 
Symptom Probable 
Cause 
Solution 
Blank screen on 
power‐up 
 
No power to unit 
 
Check for faulty 
connections 
Check power source to 
power supply 
Check for damaged 
cables 
Check connections 
On power‐up unit 
lights but does 
not communicate 
with host  
Bad cable connections to 
host port 
 
Check connections 
 
 
Misconfigured host 
Verify host 