2WIRE F-116 用户手册

下载
页码 150
Alignment and Troubleshooting
4-45
3) JAM 1
Description :   1. Recording paper is jammed in front of or inside the fuser. 
2.  Recording paper is stuck in the discharge roller and in the fuser just after 
passing through the Actuator-Feed.
1. If the recording paper is jammed in 
front of or inside the fuser.
2. If the recording paper is 
stuck in the discharge roller and the 
fuser just after passing  through the 
Actuator-Feed, Feed Actuator 
may be defective.
Replace the SMPS or Exit-Sensor.
1. Replace the Main PBA.
2. Reassemble the Actuator-Feed 
    and Spring-Actuator if the 
    movement is bad.