6) Paper rolled in the fuser
Description :   If contaminated at intervals of 77.6mm on the back of a paper.
1. Contamination of the 
pressure roller or heat roller 
(Background, Hot off set).
After disassembling the fuser, 
clean contamination between the 
heat roller and the thermostor and 
remove the contamination of the 
pressure roller.
2. Check the claw of the fuser 
whether it is deformed.
1. If there is heavy background, 
    repair it by the background 
    troubleshooting method.
2. Clean the surface of the heat 
    roller with IPA or water
3. Check the warp or separation 
    of the print claw and the holder 
    plate claw, and then manage it.