Oregon BAR388HGA 产品宣传页

下载
页码 2
Wireless Weather Station with 
Temperature / Humidity Display and     
Self-Setting Atomic Clock
Model: BAR388HGA
INTRODUCTION
Thank you for selecting this Oregon Scientific
TM 
Wireless 
Weather Station with Temperature / Humidity Display and 
Self-Setting Atomic  Clock  (BAR388HGA).  This  clock  is 
supplied  with  a  remote  sensor  (THGR122N)  and  can 
support up to 3 sensors in total (additional sensors sold 
separately).  
NOTE Please keep this manual handy as you use your new 
product. It contains practical step-by-step instructions, as 
well as technical specifications and warnings you should 
know about.
CLOCK OVERVIEW
 FRONT VIEW
1. SNOOZE
2. Weather Forecast Area
3. Outdoor Temperature Area
4. Indoor Temperature Area
5. Clock / Alarm Area
6. ALARM: View alarm status; set alarm
 BACK VIEW
 LCD DISPLAY
Weather Forecast Area:
Outdoor Temperature Area:
1.  Heat index icon
2.  Hi / lo temperature alarm
3.  Sensor reception icon
4.  Sensor battery low 
5.  Max / min icon
6.  Temperature display
7.  Ice warning is active
8.  Hi / lo humidity alarm
9.  Temperature trend
10. Humidity trend
11. Humidity display


��
��
Indoor Temperature Area:
1. Indoor sensor icon
2. Max / min icon
3. Temperature display
4. Temperature trend
5. Humidity trend
6. Humidity display
Clock / Alarm Area:
1. Alarm set
2. AM / PM icon
3. Clock signal reception
4. Low battery icon
5. Clock
6. Alarm mode icon
7. Moon phase
 REMOTE SENSOR (THGR122N)
1.  LCD
2.   LED  status  indicator: 
Blinks red during data 
transmission
 
1. Wall mount hole
2. RESET hole 
3. CHANNEL switch
4. Battery compartment
GETTING STARTED
 BATTERIES
Insert batteries before first use, matching the polarity (+ 
and -). Press RESET after each battery change.
 SENSOR DATA TRANSMISSION
 indicates main unit batteries are low.
NOTE   Do not use rechargeable batteries. We recommend 
that you use alkaline batteries with this product for longer 
usage  and  lithium  batteries  in  temperatures  below 
freezing.
REMOTE SENSOR
The sensor collects temperature readings approx. every 
40 seconds and sends them to the main unit. The main 
unit can collect data from up to 3 sensors.
To set up the sensor:
1. Remove the screws from the battery door.
2. Insert the batteries, matching the polarity  (+ / -).
 
3. Select a channel. Make sure you use a different channel 
for each sensor.
4. Place the sensor near the main unit. Press RESET on 
the sensor. 
5. Simultaneously press CHANNEL and MEM on the main 
unit to initiate signal sending between the sensor and 
main unit.
6. Close the battery door and secure the screws.
7. Place the sensor in the desired location using the table 
stand or wall mount.
For best results:
•  Place the sensor out of direct sunlight and moisture. 
•  Do not place the sensor more than 30 m (100 ft) from 
the main (indoor) unit.
•  Position  the  sensor  so  that  it  faces  the  main  (indoor) 
unit, minimizing obstructions such as doors, walls, and 
furniture.
•  Place the sensor in a location with a clear view to the 
sky, away from metallic or electronic objects.
•  Position the sensor close to the main unit during cold 
winter  months  as  below-freezing  temperatures  may 
affect battery performance and signal transmission. 
The  sensor  reception  icon  in  the  remote  sensor  area 
shows the status.
   ICON 
                         DESCRIPTION
  
                         
                         
                
 
                            
       
         and “- - . -“
         (Outdoor 
         temperature Area)
The sensor cannot be found. 
Search for the sensor or check 
batteries
To search for a sensor: 
Simultaneously, press and hold MEM and CHANNEL for 
2 seconds.
NOTE If the sensor is still not found, check the batteries, 
obstructions, and remote unit location.
CLOCK 
 CLOCK RECEPTION
This product is designed to synchronize its date and time 
automatically  once  it  is  within  range  of  the  WWVB-60 
signal from the atomic clock in Fort Collins, Colorado. 
The clock collects the radio signals whenever it is within 
3219 km (2000 miles) of a signal.
NOTE  Initial reception takes 2-10 minutes for first set up 
or when RESET is pressed. Once complete, the reception 
icon will stop blinking. If the signal is weak, it can take up 
to 24 hours to get a valid signal.
 RECEPTION SIGNAL 
To enable and force a signal search:
Press and hold   for 2 seconds.
To disable the signal reception:
Press and hold   for 2 seconds.
 STRONG SIGNAL    WEAK SIGNAL       NO SIGNAL
 SET CLOCK
If the clock signal reception is enabled and a signal is being 
received the clock does not need to be manually set. 
1.  Press and hold MODE for 2 seconds.
2.  Press   or   to change the settings.
3.  Press MODE to confirm.
4.  The settings order is: US time zone (Pacific (P), Eastern 
(E), Central (C) and Mountain (M)) offest, hour, minute, 
year, month, day and language. 
NOTE The language options are English  (E), German (D), 
French (F), Italian (I), and Spanish (S).
Press MODE to choose between the clock with seconds 
and clock with weekday display modes.
1. Pressure trend
2. Weather forecast
3. Comfort zone 
4. Pressure icon
5. Altitude icon
6. Pressure / altitude unit
7. Heat index icon
USER MANUAL
1.  
  / 
  :  Increase  /  decrease  setting;  activate  / 
 
deactivate clock reception signal
2.   MODE: Change settings / display
3.   CHANNEL: Switch remote sensor display
4.   MEM:  View  current,  maximum  and  minimum 
 
temperature / humidity
5.   PRESSURE: Select pressure unit; set altitude
6.   HEAT INDEX: Display heat index
7.   TEMP / HUMIDITY HI / LO   : Change settings or 
enable / disable hi or lo temperature / humidity alarm 
for channel 1
8.   °C / °F: Select temperature unit
9.   RESET: Reset unit to default settings
10.  Battery compartment
The  transmission  range  may  vary  depending  on  many 
factors. You may need to experiment with various locations 
to get the best results.
Standard Alkaline batteries contain significant amounts of 
water. Because of this they will freeze in low temperatures 
of  approximately  -12°C  (10°F).  Disposable  Lithium 
batteries  have  a  much  lower  threshold  for  temperature 
with an estimated freezing range of below -30°C (-22°F).
Wireless ranges can be impacted by a variety of factors 
such as extremely cold temperatures. Extreme cold may 
temporarily reduce the effective range between the sensor 
and the base station. If the unit's performance fails due to 
low temperature, the unit will resume proper functioning 
as the temperature rises to within the normal temperature 
range (i.e. no permanent damage will occur to the unit due 
to low temperatures). 
A  channel  has  been  found 
and  sensor  signal  is  being 
received
Main unit is searching 
for the sensor(s)
Clock signal reception indicator:
��
BAR388HGA_M_R5
2006.4.7, 4:35 PM
1