The  diagnostics  feature  of  your  Golden 
Companion’s  “Rhino”  microprocessor-
based motor control board functions as 
follows:
•  Any  fault  condition  on  the  “Rhino” 
controller or on an associated system 
will  cause  the  Power-on/diagnostics 
LED (see figure 43) to flash.
•  The flashing of the LED occurs as one 
flash or as a series of flashes separated 
by a two-second pause.
•  The number of flashes in each series 
is referred to as the “Flash Code.”
•  The flash code indicates the nature of 
the condition or fault.
THE FLASH CODES
1 Flash
•  Indicates that the battery voltage (with 
the thumb levers in the neutral posi-
tion) is below 23.3 volts.
•  The batteries need to be charged.
•  Your Companion will continue to op-
erate  until  the  voltage  falls  to  17.5 
volts.
•  As the voltage drops you will experi-
ence a power loss.
Remedy: Charge your Companion’s bat-
teries.  See  section  XI.  “Care 
and Maintenance.”
DIAGNOSTICS
POWER-ON/DIAGNOSTICS LED
FIGURE 44.  CHARGER LED’S
2 Flashes
•  Indicates that the battery voltage has dropped to 17.5 volts.
•  At this voltage your scooter will cease operation.
•  If you have charged the batteries and the condition continues, one or both of the 
scooter’s batteries may be at fault.
•  The continuance of this condition after you have charged your Companion’s batteries 
may also indicate a problem with the battery charger.
Remedy: Consult your authorized Golden Technologies, Inc. dealer.