Pride Mobility GC2 用户手册

下载
页码 20
Basic Operation Instructions
15
www.pridemobility.com
GC2 Controller
Fault
Probable Cause(s)
Possible Solution
Code
1 Flash
The batteries need charging.
Check the battery connections. If the
There is a bad connection
battery connections are good, then
to the batteries.
try charging the batteries.
2 Flashes
There is a bad connection on
Check the left motor connections and
the left motor.
wiring harnesses.
3 Flashes
The left motor has a short to
Contact your authorized Pride
a battery connection.
Provider.
4 Flashes
There is a bad connection on
Check the right motor connections
the right motor.
and wiring harnesses.
5 Flashes
The right motor has a short to Contact your authorized Pride
a battery connection.
Provider.
6 Flashes
The charge inhibit has been
Make sure that the battery charger
activated.
is not connected to the power base.
7 Flashes
There is a joystick fault.
Make sure the joystick is in the center
position and then power off and on
again.
8 Flashes
There is a control system fault. Check power module and joystick
module connections and wiring.
9 Flashes
The park brakes have a bad
Check the left and right motor
connection.
connections and wiring.
10 Flashes
An excessive voltage has
Check the battery connections.
been applied to the control
system.
FAULT CODES
The battery condition meter will flash fault codes when the controller system detects
an abnormal condition in the electrical system.  All of the battery condition meter
LEDs will flash a number of times quickly, then pause, then flash again. The battery
condition meter will continue to flash the fault codes until the problem is fixed. The
table below identifies the individual fault codes. If any of these fault codes persist,
contact your authorized Pride Provider.