Nikon 50i 用户手册

下载
页码 7
En
This brochure is printed on recycled paper made from 40% used material.
WARNING
TO ENSURE CORRECT USAGE, READ THE CORRESPONDING MANUALS
CAREFULLY BEFORE USING YOUR EQUIPMENT.
Specifications and equipment are subject to change without any notice or obligation
on the part of the manufacturer.  December 2003.
©2003 NIKON CORPORATION
NIKON CORPORATION
Yokohama Plant
NIKON CORPORATION
Instruments Company
ISO 9001
Accredited by the
Dutch Council for
Accreditation
ISO 14001
Printed in Japan (0312-13)T
Code No.  2CE-MSHH-1
www.nikon.com/
Fuji Bldg., 2-3, Marunouchi 3-chome, Chiyoda-ku, 
Tokyo 100-8331, Japan
NIKON CORPORATION
NIKON INSTECH CO., LTD.
Parale Mitsui Bldg., 8, Higashida-cho, Kawasaki-ku,
Kawasaki, Kanagawa 210-0005, Japan
phone: +81-44-223-2167  fax: +81-44-223-2182 
www.nikon-instruments.jp/eng/
www.i-series.com
NIKON INSTRUMENTS (SHANGHAI) CO., LTD.
CHINA  phone: +86-21-5058-5055  fax: +86-21-5058-5060
NIKON SINGAPORE PTE LTD
SINGAPORE  phone: +65-6559-3618   fax: +65-6559-3668
NIKON MALAYSIA SDN. BHD.
MALAYSIA  phone: +60-3-78763887  fax: +60-3-78763387
NIKON INSTRUMENTS EUROPE B.V.
P.O. Box  222, 1170 AE Badhoevedorp, The Netherlands
phone: +31-20-44-96-222  fax: +31-20-44-96-298
http://www.nikon-instruments.com/
NIKON FRANCE S.A.
FRANCE  phone: +33-1-45-16-45-16   fax: +33-1-45-16-00-33
NIKON GMBH
GERMANY  phone: +49-211-9414-0   fax: +49-211-9414-322
NIKON INSTRUMENTS S.p.A.
ITALY  phone: + 39-55-3009601  fax: + 39-55-300993
NIKON AG
SWITZERLAND  phone: +41-43-277-2860  fax: +41-43-277-2861
NIKON UK LTD. 
UNITED KINGDOM  phone: +44-20-8541-4440   fax: +44-20-8541-4584
NIKON INSTRUMENTS INC.
1300 Walt Whitman Road, Melville, N.Y. 11747-3064, U.S.A.
phone: +1-631-547-8500;  +1-800-52-NIKON (within the U.S.A.only)  fax: +1-631-547-0306
http://www.nikonusa.com/
NIKON CANADA INC.
CANADA  phone: +1-905-625-9910  fax: +1-905-625-0103 
* Monitor images are simulated.
Company names and product names appearing in this brochure are their registered trademarks or trademarks.
Clinical & Laboratory Microscopes ECLIPSE 50i/55i
. . . magine microscopy in perfect comfort
/
/
I
O
FIL
200
330
60
404
208
60
I
O
FIL
486
330
200
208
Dimensional Diagrams
Configured with binocular tube B
Configured with ergonomic tube 
Unit: mm
Specifications
Main body
50i
55i
Magnification
10 –1500X
Optical system
CFI60 Infinity Optical System
Coarse/fine focusing
Fine: 0.1mm per rotation, Coarse: 13.8mm per rotation, Minimum reading: 1 micron 
Coarse motion torque adjustable, Refocusing function (with stopper)
Illumination
6V-30W halogen lamp
White LED array
100-240V (worldwide voltage)
AC adapter (100-240V) or optional lithium battery (7.4V)
Built-in filter
ND8
LA60 color balance filter
Eyepiece tube
Binocular tube B (for F.O.V. 22mm)
Trinocular tube "F" UW (for F.O.V. 22mm/25mm, observation/photo: 100/0, 0/100)
Trinocular tube "T" UW (for F.O.V. 22mm/25mm, observation/photo: 100/0, 20/80, 0/100)
Ergonomic binocular tube (for F.O.V. 22mm, inclination:10-30°,  extension: 40mm); DSC port: 100/0, 50/50 (optional)
Eyepiece lens
10X (F.O.V.
:
22mm), 10X M photo mask (F.O.V.: 25mm), 12.5X (F.O.V.
:
16mm), 15X (F.O.V.
:
14.5mm),
UW 10X (F.O.V.
:
25mm), UW 10X M photo mask (F.O.V.
:
25mm)
Nosepiece
Sextuple nosepiece
Ergo-View cytodiagnostic unit (Motorized changeover 10X to 40X with hand switch, Stamp type marking 
Automatic illumination adjustment with Ergo-View
Stage
Super-hard Alumite coated surface, Stay-in-position stage handle, Stage handle height and tension adjustable
Rectangular 159mm X 243mm surface stage, 78mm X 54mm cross travel (x-y movement)
1-slide or 2-slide specimen holder available (option)
Condenser focusing stroke
27mm
Intermediate accessories
Epi-fluorescence illuminator (4 filter positions),  Magnification module, Eye-level riser, Double port
Teaching head
Observation method
Brightfield, Epi-fluorescence
Darkfield, Phase contrast, Simple polarizing
ECLIPSE i-Series Website
www.nikon-i.com
Please contact Nikon for a handy pamphlet listing compatible
accessories, including objectives and epi-fluorescence filters.
Nikon has reduced the amount of chromium, cadmium and lead used in the Eclipse-i Series
to an absolute minimum to diminish its environmental impact.
Microscopy images courtesy of :
1 Nihon University Itabashi Hospital
2 Naoyuki Miyokawa, M.D., Ph.D., Associate
Professor, Dept. of Surgical Pathology,
Asahikawa Medical College Hospital.