9-8
8XC196NP, 80C196NU USER’S MANUAL
Pulsewidth (in µs)
=
Duty Cycle (in %)
=
where:
PWM
x
_CON
=
8-bit value to load into the PWM
x
_CONTROL register
Pulsewidth
=
width of each high pulse
f
=
operating frequency, in MHz
T
PWM
=
output period on the PWM pin, in
µ
s
†
80C196NU only.
Clock Prescaler
Disabled
÷2 Clock Prescaler
Enabled
÷4 Clock Prescaler
†
Enabled
PWM
x
_CONTROL
x
= 0–2
Address:
Reset State:
Table 9-2
00H
The PWM control (PWM
x
_CONTROL) register determines the duty cycle of the PWM
x
channel. A
zero loaded into this register causes the PWM to output a low continuously (0% duty cycle). An FFH in
this register causes the PWM to have its maximum duty cycle (99.6% duty cycle).
this register causes the PWM to have its maximum duty cycle (99.6% duty cycle).
7
0
PWM Duty Cycle
Bit
Number
Function
7:0
PWM Duty Cycle
This register controls the PWM duty cycle. A zero loaded into this register causes the
PWM to output a low continuously (0% duty cycle). An FFH in this register causes the
PWM to have its maximum duty cycle (99.6% duty cycle).
PWM to output a low continuously (0% duty cycle). An FFH in this register causes the
PWM to have its maximum duty cycle (99.6% duty cycle).
Figure 9-5. PWM Control (PWM
x_CONTROL) Register
PWM
x
_C ON
2
×
f
-----------------------------------------------
PWM
x
_C ON
4
×
f
-----------------------------------------------
PWM
x
_C ON
8
×
f
-----------------------------------------------
Puls ewidth
T
PW M
---------------------------------
100
×